玉溪Sensors

more+

Linear Position Sensor

more+

玉溪KTC1/LWHPull Rod Linear Displacement Sensor 玉溪KTF Slider Displacement Sensor 玉溪KTF1 Slider Displacement Sensor 玉溪KTR11/12,KTR2 Spring Self-return Position Potentiometer 玉溪KTM Miniature Pull Rod Displacement Sensor 玉溪KTC2 Pull Rod Linear Displacement Sensor 玉溪KPC1H Hersman Plug out Pull-rod Resistance 玉溪KPC1 Articulated Electronic Ruler 玉溪KPM23 Small Articulated Resistance Sensor 玉溪KPM22 Small Articulated Resistance Sensor 玉溪KPM18 Small Articulated Resistance Sensor 玉溪KPM16 Shock Travel Sensor 玉溪KPM12 Shock Travel Sensor 玉溪KPM12R1/KPM12R2 Self-reset Resistance Sensor 玉溪WY-01 Resistive Displacement Sensor 玉溪WDL Rod Type Displacement Sensor 玉溪KSE Pull Rod Displacement Sensor 玉溪KPF Flange Displacement Sensor 玉溪KFM Micro Slider Type Resistance Sensor 玉溪KSP Circular Tube Miniature Self-reset 玉溪KSC Square Tube Miniature Self-reset Displacement sensor 玉溪KS8X Micro Self-resetting Displacement Sensor 玉溪KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 玉溪KST Self resetting displacement sensor 玉溪KSD Linear Position Sensor 13FLP 玉溪KPFZ Flange-mounted self-resetting resistance ruler 玉溪LEP displacement sensorwith Waterproof and dustproof 玉溪KEP Brushless Sensor with Waterproof and Dustproof 玉溪LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 玉溪KPM9 Mini Type Pull Rod Displacement Sensor 玉溪KSE Rod type displacement sensor 玉溪KSF Micro Slide Type Displacement Sensor 玉溪KSN Self-resetting Displacement Sensor
Rope/wire displacement sensor

more+

玉溪MPS-XXXS Pull Wire Displacement Sensor 玉溪MPS-XXS Pull Wire Displacement Sensor 玉溪MPS-XS Pull Wire Displacement Sensor 玉溪MPS-S Pull Wire Displacement Sensor 玉溪MPS-M Pull Wire Displacement Sensor 玉溪MPS-L Pull Wire Displacement Sensor 玉溪MPS-XL Pull Wire Displacement Sensor 玉溪MPSFS2-S Waterproof Absolute Wire Rope Sensor 玉溪MPSFS2-M Waterproof Absolute Wire Rope Sensor 玉溪MPSFS2-L Waterproof Absolute Wire Rope Sensor 玉溪MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 玉溪MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 玉溪MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 玉溪MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 玉溪MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 玉溪MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 玉溪MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 玉溪MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 玉溪MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 玉溪SM-S Pull Wire Displacement Sensor 玉溪SM-M Pull Wire Displacement Sensor 玉溪WEP-S Pull Wire Displacement Sensor 玉溪WEP-M Pull Wire Displacement Sensor 玉溪WS-S Pull Wire Displacement Sensor 玉溪MDS-S Pull Wire Displacement Sensor 玉溪MPS-XS Magnetic Mounting Rope Displacement Sensor 玉溪MPS-L Magnetic Draw Wire Displacement Sensor 玉溪MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 玉溪MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 玉溪MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor
玉溪Fully Automatic Lubricating Oil Pump

more+

玉溪Electric Automatic Oil Pump / Manual Oil Pump

more+

玉溪MIRAN MR-2202-2(2L) Thin Oil Lubrication Pump Controlled by PLC Type 玉溪MIRAN MR-2232-2(2L) Self-control Electric Oil Lubrication Pump 玉溪MIRAN MR-2202-3(3L) Thin Oil Electric Lubrication Pump 玉溪MIRAN MR-2232-3(3L)Self-control Electric Oil Lubrication Pump 玉溪MIRAN MRG-2202(4L) Asynchronous Dynamo Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 玉溪MIRAN MRG-2232(4L) Asynchronous Dynamo Grease and Thin Oil Lubrication Intergrated Pump 玉溪MIRAN MRG-3202(5L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 玉溪MGH-1205-100T Semi-automatic Butter Lubrication Pump 玉溪MIRAN MRG-3205(5L) Grease and Thin Oil Intergratd Pump by PLC Type 玉溪MIRAN MRG-3232(5L)Grease and Thin Oil Lubrication Intergrated Pump 玉溪MRG-3202(3L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 玉溪MIRAN MRG-3235(5L) Grease and Thin Oil Lubrication Electric Intergrated Pump 玉溪MRG-3232(3L) Self-control Grease and Thin Oil Lubrication Pump 玉溪MIRAN MRG-5202(3L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 玉溪MRG-5232-41 Self-control Grease and Thin Oil Lubrication Pump 玉溪MIRAN MRG-5202-41 (4L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 玉溪MRG-5202(5L) Self-control Grease and Thin Oil Lubrication Pump with PLC Type 玉溪MRG-5232(5L) Self-control Grease and Thin Oil Lubrication Pump 玉溪MRH-1202-100T Semi-automatic Grease Lubrication Pump 玉溪MRH-1232-100TB Automatical Grease Lubrication Pump 玉溪MGH-1202-100T Semi-automatic Butter Lubrication Pump 玉溪MGH-1232-100TB Self-control Butter Pump
Your current location is:Home>>玉溪Product>>玉溪Sensors>>玉溪Transfer module and digital display instrument

玉溪XSK Display controller digital display (single channel)

  • Product classification:Transfer module and digital display instrument
  • Number of views:1173
  • QR code:
  • Release time:2023-11-15
  • Overview

XSK Digital Display Instrument

0.2 level accuracy, measurement and control speed can be set to 10 or 40 times per second,display range -1999~9999.
Dual four-digit digital tube display (main display + second display), of which the second display can display engineering quantity units, alarm values and other information.
Universal input, selected by setting up.
Optional 1 to 4 points alarm output. 7 basic alarm modes and 4 standby alarm modes: upper limit of standby, lower limit of standby, upper limit of standby deviation, and lower limit of standby deviation. (Standby alarm mode: means that when the instrument is powered on, it does not alarm when the measured value is in the output range. When the measured value enters the non-output range, a standby condition is established, and then the alarm is normal).
10-section polyline correction function.
1 point external switch input, used for clearing.
 Peak and valley value acquisition function.
Communication and transmission are optional.

content

Code description

XSK-

Universal analog input, 0.2 level display accuracy; measurement and control speed can be set to 10 or 40 times per second

Dimension

AH

160×80×125      Hole Size:152×76      (Note①)

AS

80×160×125       Hole Size:152×76   (Note①)

 

B

96×96×76       Hole Size:92×92      (Note②)

 

CH

96×48×82       Hole Size:92×45      (Note③)

 

CS

48×96×82       Hole Size:92×45      (Note③)

 

D

72×72×75       Hole Size:68×68      (Note④)

 

E

48×48×88       Hole Size:45.5×45.5  (Note⑤)

 

Panel specifications


Dual 4-digit LED display

Contact input (optional)

K

1 point external switch input for zeroing.(When AH and CH select K, communication and transmission can only choose one option; E size does not support K option)

Alarm(option)(250V AC/3A,resistive load)

A

T1~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

B

 

T1~T2

1~2 point relay output, are normally open and closed double contacts

 

T3~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

C

T1~T2

The output of 1~2 point alarm relay is normally open and closed double contacts

T3

The output of 3 alarm relay is single open contact

T3R

The output of the 3-point alarm relay is normally open and closed double contacts

T4

4 points alarm relay output, the first 3 points are single normally open contact, the fourth point is normally open normally closed double contact

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

D

T1~T2

1~2 point alarm relay output, 1 often open and close double contact; 1 often open contact

T3

3 points of alarm relay output, 1 point is normally open and normally closed double contact, and another 2 points are single and normally open contact

O1~O3

1-3 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

E

T1~T2

1~2 point alarm relay output, 1 point often open often closed contact, the other point is normally open contact

O1~O2

1-2 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

Transmitting (optional)

(resolution: 1/3000; load capacity: 600Ω)

A1

Current output(4-20)mA、(0-10)mA、(0-20)mA

A2

Voltage output(1-5)V、(0-5)V

A3

Voltage output(0-10)V

A4

Voltage output(-5V-+5V)

A5

Voltage output(-10V-+10V)

External power supply (optional)

B1

24V±5% 50mA below

B2

12V±5% 50mA below

B3

10V±5% 50mA below

Communication (option) (the communication protocol is optional through the instrument parameters: Modbus-RTU or TC-ASCII protocol)

S1

The RS232 interface(only AH AS B size)

S2

The RS485 interface

Power Specifications

V0

100-240V AC 50/60 Hz

V1

10-24VAC 50/60Hz;10-24VDC 

Note : A size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note : B size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note :C size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3R or T4 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected one of the two, and communication can only select RS485 mode (i.e. S2)

Note : D size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected from one of the two, and communication can only select RS485 mode (i.e. S2)

Note : E size instrument

You can choose two out of three for 1-point switching input, transmission output and communication functions (communication only supports RS485 at this time)

When 2-point alarm output is selected2, external power supply cannot be selected; 1-point switching input, transmission output and communication functions can be selected two out of three (communication only supports RS485 at this time)