徐州KTC1/LWHPull Rod Linear Displacement Sensor 徐州KTC2 Pull Rod Linear Displacement Sensor 徐州KTF Slider Displacement Sensor 徐州KTF1 Slider Displacement Sensor 徐州KPC1 Articulated Electronic Ruler 徐州KPC1H Hersman Plug out Pull-rod Resistance 徐州KPM12R1/KPM12R2 Self-reset Resistance Sensor 徐州KPM16 Shock Travel Sensor 徐州KPM18 Small Articulated Resistance Sensor 徐州KPM22 Small Articulated Resistance Sensor 徐州KPM23 Small Articulated Resistance Sensor 徐州KPM12 Shock Travel Sensor 徐州WY-01 Resistive Displacement Sensor 徐州KSE Pull Rod Displacement Sensor 徐州KSC Square Tube Miniature Self-reset Displacement sensor 徐州KSP Circular Tube Miniature Self-reset 徐州KTR11/12,KTR2 Spring Self-return Position Potentiometer 徐州KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 徐州KSN Self-resetting Displacement Sensor 徐州KFM Micro Slider Type Resistance Sensor 徐州WDL Rod Type Displacement Sensor 徐州KPF Flange Displacement Sensor 徐州KTM Miniature Pull Rod Displacement Sensor 徐州KPFZ Flange-mounted self-resetting resistance ruler 徐州KSD Linear Position Sensor 13FLP 徐州KST Self resetting displacement sensor 徐州KS8X Micro Self-resetting Displacement Sensor 徐州KSE Rod type displacement sensor 徐州KPM9 Mini Type Pull Rod Displacement Sensor 徐州LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 徐州KEP Brushless Sensor with Waterproof and Dustproof 徐州LEP displacement sensorwith Waterproof and dustproof
Rope/wire displ...

more+

徐州WS-S Pull Wire Displacement Sensor 徐州MPS-XL Pull Wire Displacement Sensor 徐州MPS-L Pull Wire Displacement Sensor 徐州MPS-L Magnetic Draw Wire Displacement Sensor 徐州MPSFS2-S Waterproof Absolute Wire Rope Sensor 徐州LPS-M Pull Wire Displacement Sensor 徐州LPS-S Pull Wire Displacement Sensor 徐州MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 徐州MPS-XS Magnetic Mounting Rope Displacement Sensor 徐州MPSFS2-M Waterproof Absolute Wire Rope Sensor 徐州MPS-XXXS Pull Wire Displacement Sensor 徐州MPS-XXS Pull Wire Displacement Sensor 徐州MPS-XS Pull Wire Displacement Sensor 徐州MPS-S Pull Wire Displacement Sensor 徐州MPS-M Pull Wire Displacement Sensor 徐州MDS-S Pull Wire Displacement Sensor 徐州SM-S Pull Wire Displacement Sensor 徐州WEP-S Pull Wire Displacement Sensor 徐州WEP-M Pull Wire Displacement Sensor 徐州SM-M Pull Wire Displacement Sensor 徐州MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 徐州MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor 徐州MPSFS2-L Waterproof Absolute Wire Rope Sensor 徐州MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 徐州MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 徐州MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 徐州MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 徐州MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 徐州MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 徐州MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 徐州MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 徐州MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor
Your current location is:Home>>徐州Product>>Digital Indicator>>徐州XSEW Digital Display Instrument

徐州XSEW Digital Instrument

  • Product classification:XSEW Digital Display Instrument
  • Number of views:1301
  • QR code:
  • Release time:2023-11-14
  • Overview

XSEW Digital Display Instrument

0.05 level precision, measurement and control speed of 10 ~400 times per second can be set
Display range-99999~99999
Analog quantity is universal input, selected by setting
The 1-4-point alarm output is optional. It includes seven basic alarm methods, including measurement upper limit, measurement lower limit, deviation upper limit, deviation upper limit, deviation absolute value lower limit, fault alarm and four standby alarm methods.(Standby alarm mode: when the measured value is in the output interval, when the measured value enters the non-output interval, then the normal alarm)
Higher degree of standardization, rich functions. Including: input signal fault processing, measurement value clearance, peak, valley value acquisition, 10 section broken line correction and other functions
Optional transmission, communication

content

Code description

XSEW-

0.05 level measurement accuracy;Measurement and control speed is 10 times per second

Dimension

AH

160×80×125      Hole Size:152×76 (Note①)

CH

96×48×82       Hole Size:92×45 (Note②)

 

Panel specifications


Single 6-digit LED display

 Alarm(option)(250V AC/3A,resistive load)

AH

T1~T4

1~4 point relay output, are normally open and closed double contacts

 

01~04

Alarm is OC door output (voltage should be less than 40VDC and current should be less than 40 mA)

CH

T1~T2

1~2 point relay output, are normally open and closed double contacts

01~02

Alarm is OC door output (voltage should be less than 40VDC and current should be less than 40 mA)

T3

3 point relay output is a single open contact.

03

Alarm is OC door output (voltage should be less than 40VDC and current should be less than 40 mA)

Contact input (optional)

K

1 point external switch quantity input for reset

Transmitting (optional)

(resolution: 1/3000; load capacity: 600Ω)(Suitable for the measurement and control speed of 200 times per second and above the transmission speed)

A1

Current output(4-20)mA、(0-10)mA、(0-20)mA

A2

Voltage output(1-5)V、(0-5)V

A3

Voltage output(0-10)V

A4

 

Voltage output (-5V-+5V)

A5

Voltage output (-10V-10V)

Quick delivery (optional)

F

Suitable for the measurement and control speed of 200 times per second and above the transmission speed

External power supply (optional)

B1

24V±5% 50mA below

B2

12V±5% 50mA below

B3

10V±5% 50mA below

Communication (option)

(Optional via instrument parameters: Modbus-RTU or TC-ASCII communication protocol)

S1

RS232 interface (only AH size)

S2

RS485 interface

Power Specifications

V0

100-240V AC 50/60 Hz

V1

10-24VAC 50/60Hz;10-24VDC 

Note①:A size instrument

When selecting 1-point switching input, the instrument’s transmission output and communication functions can only be selected from one of the two.
Note②:C size instrument
When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (communication only supports RS485 at this time)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)