TEL:

180 3818 6775

Announcement:

Product

Sensors

more+

Rope/wire displacement sensor

more+

MPS-XXXS Pull Wire Displacement Sensor MPS-XXS Pull Wire Displacement Sensor MPS-XS Pull Wire Displacement Sensor MPS-S Pull Wire Displacement Sensor MPS-M Pull Wire Displacement Sensor MPS-L Pull Wire Displacement Sensor MPS-XL Pull Wire Displacement Sensor MPSFS2-S Waterproof Absolute Wire Rope Sensor MPSFS2-M Waterproof Absolute Wire Rope Sensor MPSFS2-L Waterproof Absolute Wire Rope Sensor MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor SM-S Pull Wire Displacement Sensor SM-M Pull Wire Displacement Sensor WEP-S Pull Wire Displacement Sensor WEP-M Pull Wire Displacement Sensor WS-S Pull Wire Displacement Sensor MDS-S Pull Wire Displacement Sensor MPS-XS Magnetic Mounting Rope Displacement Sensor MPS-L Magnetic Draw Wire Displacement Sensor MPS-M Plastic Protective Cover Pull Wire Displacement Sensor MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor
Fully Automatic Lubricating Oil Pump

more+

Electric Automatic Oil Pump / Manual Oil Pump

more+

Your current location is:Home>>Product>>Digital Indicator>>XSEW Digital Display Instrument

XSEW Digital Instrument

  • Product classification:XSEW Digital Display Instrument
  • Number of views:1592
  • QR code:
  • Release time:2023-11-14
  • Overview

XSEW Digital Display Instrument

0.05 level precision, measurement and control speed of 10 ~400 times per second can be set
Display range-99999~99999
Analog quantity is universal input, selected by setting
The 1-4-point alarm output is optional. It includes seven basic alarm methods, including measurement upper limit, measurement lower limit, deviation upper limit, deviation upper limit, deviation absolute value lower limit, fault alarm and four standby alarm methods.(Standby alarm mode: when the measured value is in the output interval, when the measured value enters the non-output interval, then the normal alarm)
Higher degree of standardization, rich functions. Including: input signal fault processing, measurement value clearance, peak, valley value acquisition, 10 section broken line correction and other functions
Optional transmission, communication

content

Code description

XSEW-

0.05 level measurement accuracy;Measurement and control speed is 10 times per second

Dimension

AH

160×80×125      Hole Size:152×76 (Note①)

CH

96×48×82       Hole Size:92×45 (Note②)

 

Panel specifications


Single 6-digit LED display

 Alarm(option)(250V AC/3A,resistive load)

AH

T1~T4

1~4 point relay output, are normally open and closed double contacts

 

01~04

Alarm is OC door output (voltage should be less than 40VDC and current should be less than 40 mA)

CH

T1~T2

1~2 point relay output, are normally open and closed double contacts

01~02

Alarm is OC door output (voltage should be less than 40VDC and current should be less than 40 mA)

T3

3 point relay output is a single open contact.

03

Alarm is OC door output (voltage should be less than 40VDC and current should be less than 40 mA)

Contact input (optional)

K

1 point external switch quantity input for reset

Transmitting (optional)

(resolution: 1/3000; load capacity: 600Ω)(Suitable for the measurement and control speed of 200 times per second and above the transmission speed)

A1

Current output(4-20)mA、(0-10)mA、(0-20)mA

A2

Voltage output(1-5)V、(0-5)V

A3

Voltage output(0-10)V

A4

 

Voltage output (-5V-+5V)

A5

Voltage output (-10V-10V)

Quick delivery (optional)

F

Suitable for the measurement and control speed of 200 times per second and above the transmission speed

External power supply (optional)

B1

24V±5% 50mA below

B2

12V±5% 50mA below

B3

10V±5% 50mA below

Communication (option)

(Optional via instrument parameters: Modbus-RTU or TC-ASCII communication protocol)

S1

RS232 interface (only AH size)

S2

RS485 interface

Power Specifications

V0

100-240V AC 50/60 Hz

V1

10-24VAC 50/60Hz;10-24VDC 

Note①:A size instrument

When selecting 1-point switching input, the instrument’s transmission output and communication functions can only be selected from one of the two.
Note②:C size instrument
When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (communication only supports RS485 at this time)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)



  • Application
Prev:no morer
Next:no morer