TEL:

180 3818 6775

Announcement:

Product

Sensors

more+

Rope/wire displacement sensor

more+

MPS-XXXS Pull Wire Displacement Sensor MPS-XXS Pull Wire Displacement Sensor MPS-XS Pull Wire Displacement Sensor MPS-S Pull Wire Displacement Sensor MPS-M Pull Wire Displacement Sensor MPS-L Pull Wire Displacement Sensor MPS-XL Pull Wire Displacement Sensor MPSFS2-S Waterproof Absolute Wire Rope Sensor MPSFS2-M Waterproof Absolute Wire Rope Sensor MPSFS2-L Waterproof Absolute Wire Rope Sensor MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor SM-S Pull Wire Displacement Sensor SM-M Pull Wire Displacement Sensor WEP-S Pull Wire Displacement Sensor WEP-M Pull Wire Displacement Sensor WS-S Pull Wire Displacement Sensor MDS-S Pull Wire Displacement Sensor MPS-XS Magnetic Mounting Rope Displacement Sensor MPS-L Magnetic Draw Wire Displacement Sensor MPS-M Plastic Protective Cover Pull Wire Displacement Sensor MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor
Fully Automatic Lubricating Oil Pump

more+

Electric Automatic Oil Pump / Manual Oil Pump

more+

Your current location is:Home>>Product>>Digital Indicator>>XSAE Displacement Sensor Digital Display Instrument

XSAE Displacement Sensor Digital Display Instrument

  • Product classification:XSAE Displacement Sensor Digital Display Instrument
  • Number of views:1244
  • QR code:
  • Release time:2023-11-14
  • Overview

XSAE Displacement Sensor Digital  Display Instrument

Paired with resistance scale, eddy current displacement sensor, etc. 0.05 level accuracy, measurement and control speed 10 times per second. Display range -19999~45000. Panel keys and switch input zero setting function. 8-segment polyline correction function. Optional 1 to 4 alarm output points. There are five basic alarm modes and five standby alarm modes corresponding to the five basic alarm modes. (Standby alarm mode: means that when the instrument is powered on, it will not alarm even if it is in the alarm area. When the measured value enters the non-alarm area, the standby condition will be established, and then it will alarm normally). 4 optional external power supplies. Optional communication, transmission and printing functions.

■ Connecting with  resistance scale, eddy current displacement sensor, etc.

■ 0.2 level accuracy, measuring and controlling speed can be reached at 10 times per second. Display range -1999~9999

■ Panel button and digital input zero function

■ 8-band polyline correction function

■ Optional can be choosen from  1 to 4 alarm output. Including the upper limit of measurement value, the lower limit of measurement value, the upper limit of deviation, the lower limit of deviation, the absolute value of deviation, five basic alarm modes and five standby alarm modes corresponding to five basic alarm modes

(Standby alarm mode: When the instrument is powered on, it will not alarm even if it is in the alarm area. When the measured value enters the non-alarm area, the standby condition is established, and then the alarm is normal.)

4 optional external power supplies

Optional communication, transmission and printing functions.

 

content

code description

XSAE-

0.05 level measurement accuracy; 10 times per second measurement and control speed

Diemnsion

AH

160×80×125      Hole Size:152×76

CH

96×48×112       Hole Size:92×45

Panel specification


Digit LED

Signal input(Other input signals, instructions when ordering)


I

DC(4-20)mA、(0-10)mA、(0-20)mA

V

DC Voltage(0-5)V、(1-5)V

W

Potentiometer(500Ω~10kΩ

Contact input (optional)

K

1 point external switch input for zeroing.

 Alarm(optional)

T1~4

T3、T4 limit AH   (250V AC/3A,Resistance load)

Transmitting (optional)

(resolution: 1/3000; load capacity: 600Ω

A1

Current output(4-20)mA、(0-10)mA、(0-20)mA

A2

Voltage output(1-5)V、(0-5)V

A3

Voltage output(0-10)V

External power supply (optional)

(No external power supply is required when the input signal is W (potentiometer)

B1

24V±5% 50mA below

B1G

24V±5% 100mA below

B2

12V±5% 50mA below

B2G

12V±5% 100mA below

Communication (optional)

(communication rate: 2400, 4800, 9600, 19200)

(Address: 0-99)

S1

TC ASCII Protocol RS232

S2

TC ASCII Protocol RS485

M1

Modbus-RTU Protocol RS232

M2

Modbus-RTU Protocol RS485

 Print interface (optional)

P


Power Specifications

V0

100-240V AC 50/60 Hz

V1

10-24V AC 50/60 Hz;10-24V DC(limit CH)


  • Application