Intrinsic safety explosion-proof external displacement sensor transmission module description: Ordinary linear displacement sensors, electronic rulers, resistance rulers and pull cord/guy wire displacement sensors are all displacement sensors based on the potentiometer principle. They are actually equivalent to a potentiometer. In layman's terms, it is also called: sliding rheostat. The output voltage is 0-5V depending on the voltage supplied by it. That is, if the customer's power supply voltage is 5V, the output is directly 0-5V. If the supply voltage is 10V, the output is 0-10V. If the supply voltage is 24V, the output is 0-24V. If the power supply voltage is only 24V and there is no 5V or 10V power supply, but the output wants 0-5V or 0-10V and 4-20mA, RS485, then you need to use our module.
BAMO Dimensions of intrinsically safe explosion-proof external signal transmission module:
Certificate for intrinsically safe explosion-proof external displacement sensor transmission module: