日照The Correct Way to Install a Fixed Electronic Ruler and Common Problems

Release Date:2024-06-25 Click:1067

Fixed installation method:

1. Feet must be horizontal fixed installation

2. The lever in traction hole must be one of pull rod; 

3. The choice of electronic scale effective stroke must be greater than the oil cylinder stroke more than 10 mm effectively. The buffer area before and after the installation must be larger than 5mm. 

4. Carbon film circuit board face when installation must stand sideways or down (to avoid pollution of dust or carbon powder fell on the carbon film on the working plane).


KTC1 series

Correct installation method of top surface

image.png

    Proper side mounting method                                                                                

image.png

  Incorrect installation method on the bottom surface

image.png


KTF series

Proper side mounting method

image.png

Correct installation method of the bottom surface                                         

image.png

   Top surface incorrect installation method

 image.png