TEL:

180 3818 6775

Announcement:

Product

全州Sensors

more+

Linear Position Sensor

more+

全州KTC1/LWHPull Rod Linear Displacement Sensor 全州KTF Slider Displacement Sensor 全州KTF1 Slider Displacement Sensor 全州KTR11/12,KTR2 Spring Self-return Position Potentiometer 全州KTM Miniature Pull Rod Displacement Sensor 全州KTC2 Pull Rod Linear Displacement Sensor 全州KPC1H Hersman Plug out Pull-rod Resistance 全州KPC1 Articulated Electronic Ruler 全州KPM23 Small Articulated Resistance Sensor 全州KPM22 Small Articulated Resistance Sensor 全州KPM18 Small Articulated Resistance Sensor 全州KPM16 Shock Travel Sensor 全州KPM12 Shock Travel Sensor 全州KPM12R1/KPM12R2 Self-reset Resistance Sensor 全州WY-01 Resistive Displacement Sensor 全州WDL Rod Type Displacement Sensor 全州KSE Pull Rod Displacement Sensor 全州KPF Flange Displacement Sensor 全州KFM Micro Slider Type Resistance Sensor 全州KSP Circular Tube Miniature Self-reset 全州KSC Square Tube Miniature Self-reset Displacement sensor 全州KSF Micro Slide Type Displacement Sensor 全州KS8X Micro Self-resetting Displacement Sensor 全州KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 全州KST Self resetting displacement sensor 全州KSD Linear Position Sensor 13FLP 全州KPFZ Flange-mounted self-resetting resistance ruler 全州LEP displacement sensorwith Waterproof and dustproof 全州KEP Brushless Sensor with Waterproof and Dustproof 全州LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 全州KPM9 Mini Type Pull Rod Displacement Sensor 全州KSE Rod type displacement sensor 全州KSN Self-resetting Displacement Sensor
Rope/wire displacement sensor

more+

全州MPS-XXXS Pull Wire Displacement Sensor 全州MPS-XXS Pull Wire Displacement Sensor 全州MPS-XS Pull Wire Displacement Sensor 全州MPS-S Pull Wire Displacement Sensor 全州MPS-M Pull Wire Displacement Sensor 全州MPS-L Pull Wire Displacement Sensor 全州MPS-XL Pull Wire Displacement Sensor 全州MPSFS2-S Waterproof Absolute Wire Rope Sensor 全州MPSFS2-M Waterproof Absolute Wire Rope Sensor 全州MPSFS2-L Waterproof Absolute Wire Rope Sensor 全州MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 全州MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 全州MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 全州MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 全州MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 全州MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 全州MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 全州MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 全州MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 全州SM-S Pull Wire Displacement Sensor 全州SM-M Pull Wire Displacement Sensor 全州WEP-S Pull Wire Displacement Sensor 全州WEP-M Pull Wire Displacement Sensor 全州WS-S Pull Wire Displacement Sensor 全州MDS-S Pull Wire Displacement Sensor 全州MPS-XS Magnetic Mounting Rope Displacement Sensor 全州MPS-L Magnetic Draw Wire Displacement Sensor 全州MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 全州MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 全州MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor
全州Fully Automatic Lubricating Oil Pump

more+

Your current location is:Home>>全州Product>>全州Sensors>>全州Inductive frequency modulation displacement sensor

全州Inductive frequency modulation displacement sensor

  • Product classification:Inductive frequency modulation displacement sensor
  • Number of views:127
  • QR code:
  • Release time:2024-10-19
  • Overview

ML-F-50MM Inductive frequency modulation displacement sensor:


Application areas: Used on static load testers, in nuclear explosion tests, in geotechnical and in-situ testing, and in industrial and other fields.

         

Inductive frequency modulation displacement sensors can be widely used in national defense engineering scientific experiments, engineering survey and design geotechnical tests, and in-situ testing in various industries and industrial automation and measurement and control technology fields. Becoming an ideal choice for intelligent secondary instruments and supporting products in the microcomputer application department.

The inductive frequency modulation displacement sensor has excellent performance, using a convenient single power supply of 12V DC. The electronic circuit is sealed in a 304 stainless steel metal tube, and has waterproof, anti-corrosion, and explosion-proof properties.

1729300098472107.jpg

Characteristics of ML-F Inductive Frequency Modulation Displacement Sensor:

1. Outer diameter Φ 21mm, stainless steel 304 shell, rebound type.

2. Accurate detection: The repeatability and return error are very small, with errors less than 0.05%; The nonlinear error ranges from 0.1% to 1.0%. 3. Remote transmission does not affect testing accuracy and has high resolution.

4. Reliable in operation, due to its simple and compact structure, tight packaging, earthquake resistance and moisture resistance, it is particularly suitable for use in harsh environments.

5. Stable performance. Save power and cables


Technical parameters :


Stroke Length

50mm,100mm

Output Signal

Square wave signal with amplitude greater than 2V

Resolution

≤0.01MM

Linearity Error

0.1%---1.0%

Power Supply

12V DC

Working Current

≤5mA

Shock Resistance

250g/11ms

Vibration Tolerance

10g/2KHZ

Center frequency

16KHZ ±4%

Temperature Coefficient

Zero Point≤0.01%/℃

Allow cable length

≤1000 Meter

Operation temperature

-25℃~+85℃



Instructions for use:

1. Voltage and signal waveform: Power supply is 12V DC, square wave signal output

2. Installation: The sensor is fixed with a dial gauge holder or a magnetic gauge holder

3. Wiring: The sensor wire is a two core microphone wire, shielded as a ground wire, connected to the low terminal of the power and signal. One core wire is connected to the positive pole of the power supply, and the other is connected to the signal input terminal. The plug outputs, with one pin connected to the signal, two pins connected to the power supply, and three and four pins connected to the ground

4. The reading should be taken 30 minutes after power on

5. The factory comes with a 5-meter cable. If it is not enough, it should be declared in advance for extension

6. Properly protect, prevent falling, and strictly use according to technical conditions


Mechanical installation dimensions :
电感调频式位移传感器尺寸图.jpg

Miran displacement sensor calibration table

Sensor model: ML-F-50MM

① Within the range of -10~50 ℃, the average frequency drift per degree is 0.1Hz/℃

② Frequency drift of 1Hz for 4 hours at room temperature of 20 ℃

③ Rating Results Table



1704878689892186.png


  • Application
Prev:no morer
Next:no morer