MPS-XXXS Pull Wire Displacement Sensor MPS-XXS Pull Wire Displacement Sensor MPS-XS Pull Wire Displacement Sensor MPS-S Pull Wire Displacement Sensor MPS-M Pull Wire Displacement Sensor MPS-L Pull Wire Displacement Sensor MPS-XL Pull Wire Displacement Sensor MPSFS2-S Waterproof Absolute Wire Rope Sensor MPSFS2-M Waterproof Absolute Wire Rope Sensor MPSFS2-L Waterproof Absolute Wire Rope Sensor MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor SM-S Pull Wire Displacement Sensor SM-M Pull Wire Displacement Sensor WEP-S Pull Wire Displacement Sensor WEP-M Pull Wire Displacement Sensor WS-S Pull Wire Displacement Sensor MDS-S Pull Wire Displacement Sensor MPS-XS Magnetic Mounting Rope Displacement Sensor MPS-L Magnetic Draw Wire Displacement Sensor MPS-M Plastic Protective Cover Pull Wire Displacement Sensor MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor
Fully Automatic Lubricating Oil Pump

more+

Electric Automatic Oil Pump / Manual Oil Pump

more+

Your current location is:Home>>Product>>Digital Indicator>>XSAW Potentiometer Digital Display Instrument

XSAW Potentiometer Digital Display Instrument

  • Product classification:XSAW Potentiometer Digital Display Instrument
  • Number of views:1370
  • QR code:
  • Release time:2023-11-14
  • Overview

XSAW Potentiometer Digital Display Instrument

▪Connect resistance ruler, potentiometer
▪0.2 level precision, measurement and control speed can be set 5-200 times per second. Display range-1999~9999
▪Panel button and switch quantity input set zero function
▪The 10-point broken line correction function
▪The 1-4-point alarm output is optional. It includes six basic alarm methods, including upper measurement value, lower measurement value, upper deviation limit, lower deviation limit, upper absolute deviation limit and lower absolute deviation value, and four standby upper and lower limit, and upper and lower standby deviation methods.(Standby alarm mode: when the value instrument is energized, even in the alarm area. When the measured value enters the unalarm area, the standby condition is established, and then normal alarm)
▪It showed improved stability and anti-interference ability compared to XSA

content

Code description

XSAW-

0.2 level measurement accuracy; Double display

Dimension

AH

 160×80×125              Hole Size:152×76

CH

  96×48×82        Hole Size:92×45

E

 48×48×88      Hole Size:45.5×45.5

Panel specifications

1

Double Standard  4 Digit LED(Main display window Second display window)

Signal input(Other input singals instructions when ordering)

 

W

potentiometer(500Ω~10kΩ)

Contact input (optional)

K1

1 point external switch input for zeroing.(When AH and CH select K, communication and transmission can only choose one option; E size does not support K option)

 Alarm(option)

AH

T1~T4

1~4 point relay output, are normally open and closed double contacts

CH

T1~T2

1~2 point relay output, are normally open and closed double contacts

T3

3 point relay output is a single open contact.

E

T1

1 point relay output is a single open contact. See Note ① for details

T2

2 point relay output is a single open contact.See Note ① for details

Transmitting (optional)

(resolution: 1/3000; load capacity: 600Ω

A1

Current output(4-20)mA、(0-10)mA、(0-20)mA

A2

Voltage output(1-5)V、(0-5)V

A3

Voltage output(0-10)V

Communication (optional)

(communication rate: 2400, 4800, 9600, 19200)

(Address: 0-99)

S1

The RS232 interface can select the TCASCII or Modbus-RTU through the software settings (AH, CH size only)

S2

The RS485 interface can select the TCASCII or Modbus-RTU through the software settings

Power Specifications

V0

100-240V AC 50/60 Hz

V1

10-24VAC 50/60Hz;10-24VDC

Installation Size

-AP

The plate(E size only)


Note ①: E size instrument, select alarm:
when selecting 1 point relay output, transmission output and communication function can only be selected (communication only supports RS485);
when selecting 2 point relay output, cannot select communication and transmission.