茂名KTC1/LWHPull Rod Linear Displacement Sensor 茂名KTC2 Pull Rod Linear Displacement Sensor 茂名KTF Slider Displacement Sensor 茂名KTF1 Slider Displacement Sensor 茂名KPC1 Articulated Electronic Ruler 茂名KPC1H Hersman Plug out Pull-rod Resistance 茂名KPM12R1/KPM12R2 Self-reset Resistance Sensor 茂名KPM16 Shock Travel Sensor 茂名KPM18 Small Articulated Resistance Sensor 茂名KPM22 Small Articulated Resistance Sensor 茂名KPM23 Small Articulated Resistance Sensor 茂名KPM12 Shock Travel Sensor 茂名WY-01 Resistive Displacement Sensor 茂名KSE Pull Rod Displacement Sensor 茂名KSC Square Tube Miniature Self-reset Displacement sensor 茂名KSP Circular Tube Miniature Self-reset 茂名KTR11/12,KTR2 Spring Self-return Position Potentiometer 茂名KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 茂名KSN Self-resetting Displacement Sensor 茂名KFM Micro Slider Type Resistance Sensor 茂名WDL Rod Type Displacement Sensor 茂名KPF Flange Displacement Sensor 茂名KTM Miniature Pull Rod Displacement Sensor 茂名KPFZ Flange-mounted self-resetting resistance ruler 茂名KSD Linear Position Sensor 13FLP 茂名KST Self resetting displacement sensor 茂名KS8X Micro Self-resetting Displacement Sensor 茂名KSE Rod type displacement sensor 茂名KPM9 Mini Type Pull Rod Displacement Sensor 茂名LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 茂名KEP Brushless Sensor with Waterproof and Dustproof 茂名LEP displacement sensorwith Waterproof and dustproof
Rope/wire displ...

more+

茂名WS-S Pull Wire Displacement Sensor 茂名MPS-XL Pull Wire Displacement Sensor 茂名MPS-L Pull Wire Displacement Sensor 茂名MPS-L Magnetic Draw Wire Displacement Sensor 茂名MPSFS2-S Waterproof Absolute Wire Rope Sensor 茂名LPS-M Pull Wire Displacement Sensor 茂名LPS-S Pull Wire Displacement Sensor 茂名MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 茂名MPS-XS Magnetic Mounting Rope Displacement Sensor 茂名MPSFS2-M Waterproof Absolute Wire Rope Sensor 茂名MPS-XXXS Pull Wire Displacement Sensor 茂名MPS-XXS Pull Wire Displacement Sensor 茂名MPS-XS Pull Wire Displacement Sensor 茂名MPS-S Pull Wire Displacement Sensor 茂名MPS-M Pull Wire Displacement Sensor 茂名MDS-S Pull Wire Displacement Sensor 茂名SM-S Pull Wire Displacement Sensor 茂名WEP-S Pull Wire Displacement Sensor 茂名WEP-M Pull Wire Displacement Sensor 茂名SM-M Pull Wire Displacement Sensor 茂名MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 茂名MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor 茂名MPSFS2-L Waterproof Absolute Wire Rope Sensor 茂名MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 茂名MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 茂名MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 茂名MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 茂名MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 茂名MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 茂名MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 茂名MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 茂名MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor
Your current location is:Home>>茂名Product>>Digital Indicator>>茂名XSEW Digital Display Instrument

茂名XSEW Digital Instrument

  • Product classification:XSEW Digital Display Instrument
  • Number of views:1077
  • QR code:
  • Release time:2023-11-14
  • Overview

XSEW Digital Display Instrument

0.05 level precision, measurement and control speed of 10 ~400 times per second can be set
Display range-99999~99999
Analog quantity is universal input, selected by setting
The 1-4-point alarm output is optional. It includes seven basic alarm methods, including measurement upper limit, measurement lower limit, deviation upper limit, deviation upper limit, deviation absolute value lower limit, fault alarm and four standby alarm methods.(Standby alarm mode: when the measured value is in the output interval, when the measured value enters the non-output interval, then the normal alarm)
Higher degree of standardization, rich functions. Including: input signal fault processing, measurement value clearance, peak, valley value acquisition, 10 section broken line correction and other functions
Optional transmission, communication

content

Code description

XSEW-

0.05 level measurement accuracy;Measurement and control speed is 10 times per second

Dimension

AH

160×80×125      Hole Size:152×76 (Note①)

CH

96×48×82       Hole Size:92×45 (Note②)

 

Panel specifications


Single 6-digit LED display

 Alarm(option)(250V AC/3A,resistive load)

AH

T1~T4

1~4 point relay output, are normally open and closed double contacts

 

01~04

Alarm is OC door output (voltage should be less than 40VDC and current should be less than 40 mA)

CH

T1~T2

1~2 point relay output, are normally open and closed double contacts

01~02

Alarm is OC door output (voltage should be less than 40VDC and current should be less than 40 mA)

T3

3 point relay output is a single open contact.

03

Alarm is OC door output (voltage should be less than 40VDC and current should be less than 40 mA)

Contact input (optional)

K

1 point external switch quantity input for reset

Transmitting (optional)

(resolution: 1/3000; load capacity: 600Ω)(Suitable for the measurement and control speed of 200 times per second and above the transmission speed)

A1

Current output(4-20)mA、(0-10)mA、(0-20)mA

A2

Voltage output(1-5)V、(0-5)V

A3

Voltage output(0-10)V

A4

 

Voltage output (-5V-+5V)

A5

Voltage output (-10V-10V)

Quick delivery (optional)

F

Suitable for the measurement and control speed of 200 times per second and above the transmission speed

External power supply (optional)

B1

24V±5% 50mA below

B2

12V±5% 50mA below

B3

10V±5% 50mA below

Communication (option)

(Optional via instrument parameters: Modbus-RTU or TC-ASCII communication protocol)

S1

RS232 interface (only AH size)

S2

RS485 interface

Power Specifications

V0

100-240V AC 50/60 Hz

V1

10-24VAC 50/60Hz;10-24VDC 

Note①:A size instrument

When selecting 1-point switching input, the instrument’s transmission output and communication functions can only be selected from one of the two.
Note②:C size instrument
When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (communication only supports RS485 at this time)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)



  • Application