TEL:

180 3818 6775

Announcement:

Product

六盘水Sensors

more+

Linear Position Sensor

more+

六盘水KTC1/LWHPull Rod Linear Displacement Sensor 六盘水KTF Slider Displacement Sensor 六盘水KTF1 Slider Displacement Sensor 六盘水KTR11/12,KTR2 Spring Self-return Position Potentiometer 六盘水KTM Miniature Pull Rod Displacement Sensor 六盘水KTC2 Pull Rod Linear Displacement Sensor 六盘水KPC1H Hersman Plug out Pull-rod Resistance 六盘水KPC1 Articulated Electronic Ruler 六盘水KPM23 Small Articulated Resistance Sensor 六盘水KPM22 Small Articulated Resistance Sensor 六盘水KPM18 Small Articulated Resistance Sensor 六盘水KPM16 Shock Travel Sensor 六盘水KPM12 Shock Travel Sensor 六盘水KPM12R1/KPM12R2 Self-reset Resistance Sensor 六盘水WY-01 Resistive Displacement Sensor 六盘水WDL Rod Type Displacement Sensor 六盘水KSE Pull Rod Displacement Sensor 六盘水KPF Flange Displacement Sensor 六盘水KFM Micro Slider Type Resistance Sensor 六盘水KSP Circular Tube Miniature Self-reset 六盘水KSC Square Tube Miniature Self-reset Displacement sensor 六盘水KS8X Micro Self-resetting Displacement Sensor 六盘水KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 六盘水KST Self resetting displacement sensor 六盘水KSD Linear Position Sensor 13FLP 六盘水KPFZ Flange-mounted self-resetting resistance ruler 六盘水LEP displacement sensorwith Waterproof and dustproof 六盘水KEP Brushless Sensor with Waterproof and Dustproof 六盘水LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 六盘水KPM9 Mini Type Pull Rod Displacement Sensor 六盘水KSE Rod type displacement sensor 六盘水KSF Micro Slide Type Displacement Sensor 六盘水KSN Self-resetting Displacement Sensor
Rope/wire displacement sensor

more+

六盘水MPS-XXXS Pull Wire Displacement Sensor 六盘水MPS-XXS Pull Wire Displacement Sensor 六盘水MPS-XS Pull Wire Displacement Sensor 六盘水MPS-S Pull Wire Displacement Sensor 六盘水MPS-M Pull Wire Displacement Sensor 六盘水MPS-L Pull Wire Displacement Sensor 六盘水MPS-XL Pull Wire Displacement Sensor 六盘水MPSFS2-S Waterproof Absolute Wire Rope Sensor 六盘水MPSFS2-M Waterproof Absolute Wire Rope Sensor 六盘水MPSFS2-L Waterproof Absolute Wire Rope Sensor 六盘水MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 六盘水MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 六盘水MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 六盘水MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 六盘水MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 六盘水MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 六盘水MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 六盘水MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 六盘水MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 六盘水SM-S Pull Wire Displacement Sensor 六盘水SM-M Pull Wire Displacement Sensor 六盘水WEP-S Pull Wire Displacement Sensor 六盘水WEP-M Pull Wire Displacement Sensor 六盘水WS-S Pull Wire Displacement Sensor 六盘水MDS-S Pull Wire Displacement Sensor 六盘水MPS-XS Magnetic Mounting Rope Displacement Sensor 六盘水MPS-L Magnetic Draw Wire Displacement Sensor 六盘水MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 六盘水MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 六盘水MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor
六盘水Fully Automatic Lubricating Oil Pump

more+

六盘水Electric Automatic Oil Pump / Manual Oil Pump

more+

六盘水MIRAN MR-2202-2(2L) Thin Oil Lubrication Pump Controlled by PLC Type 六盘水MIRAN MR-2232-2(2L) Self-control Electric Oil Lubrication Pump 六盘水MIRAN MR-2202-3(3L) Thin Oil Electric Lubrication Pump 六盘水MIRAN MR-2232-3(3L)Self-control Electric Oil Lubrication Pump 六盘水MIRAN MRG-2202(4L) Asynchronous Dynamo Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 六盘水MIRAN MRG-2232(4L) Asynchronous Dynamo Grease and Thin Oil Lubrication Intergrated Pump 六盘水MIRAN MRG-3202(5L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 六盘水MGH-1205-100T Semi-automatic Butter Lubrication Pump 六盘水MIRAN MRG-3205(5L) Grease and Thin Oil Intergratd Pump by PLC Type 六盘水MIRAN MRG-3232(5L)Grease and Thin Oil Lubrication Intergrated Pump 六盘水MRG-3202(3L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 六盘水MIRAN MRG-3235(5L) Grease and Thin Oil Lubrication Electric Intergrated Pump 六盘水MRG-3232(3L) Self-control Grease and Thin Oil Lubrication Pump 六盘水MIRAN MRG-5202(3L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 六盘水MRG-5232-41 Self-control Grease and Thin Oil Lubrication Pump 六盘水MIRAN MRG-5202-41 (4L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 六盘水MRG-5202(5L) Self-control Grease and Thin Oil Lubrication Pump with PLC Type 六盘水MRG-5232(5L) Self-control Grease and Thin Oil Lubrication Pump 六盘水MRH-1202-100T Semi-automatic Grease Lubrication Pump 六盘水MRH-1232-100TB Automatical Grease Lubrication Pump 六盘水MGH-1202-100T Semi-automatic Butter Lubrication Pump 六盘水MGH-1232-100TB Self-control Butter Pump
Your current location is:Home>>六盘水Product>>六盘水Sensors>>Magnetostrictive displacement/liquid level sensor

六盘水MTL5 Reinforced Sealed Magnetostrictive

  • Product classification:Magnetostrictive displacement/liquid level sensor
  • Number of views:972
  • QR code:
  • Release time:2023-11-14
  • Overview

MTL5 Reinforced sealing magnetostrictive displacement sensor overview:


In ferromagnetic material, the change of magnetization direction will cause the change of dielectric lattice spacing, so that the length and volume of ferromagnetic material change, namely: magnetostriction phenomenon, also known as the Widman effect, and its inverse effect is known as the Villari effect.

The principle of magnetostrictive displacement sensor is to generate a strain pulse signal when two different magnetic fields intersect, and then calculate the time period required for this signal to be detected, so as to calculate the exact position. One comes from a permanent magnet in the ring and the other from an 

excitation pulse generated by an electronic component in the sensor's electronics chamber. The excitation pulse runs at the speed of sound along a waveguide wire made of magnetostrictive material inside the sensor. When intersecting with the permanent magnetic field in the magnetic ring, the mechanical vibration generated by the waveguide wire forms a strain pulse due to the magnetostriction phenomenon. The strain pulse is quickly detected by a sensing circuit in the electronic chamber. Multiply the total time from the moment the excitation pulse is generated until the strain pulse is detected by a fixed speed of sound, and we can accurately calculate the position change of the magnet. The process is continuous, so every time the position of the ring changes, a new position is quickly measured. Since the output signal is the true position value, rather than a proportional or re-amplified signal, there is no signal drift or change of value, let alone the need to periodically resold as with other sensors.

 

Magnetostrictive sensor is non-contact, never wear. It has the advantages of high resolution, high precision, high stability, high reliability, fast response time and 

long working life. Sensors do not need to be re-calibrated or regularly maintained.




Performance parameter

 

1. Measuring range :30 ~ 3000mm


2. Power supply voltage: +12VDC ~ +24VDC
 
3. Output form/analog signal: current 4-20mA and 0-20mA, voltage 0-5V and 0-10V, digital signal: RS485
 
4. Load capacity: Voltage signal output load ≥4 KΩ Current signal output load ≤500 Ω
 
5. Nonlinear error :≤0.05%FS
 
6. Repeatability error :≤0.0005%FS
 
7. Resolution :≤0.038mm
 
8. Hysteresis: acuities were 0.001% FS
 
9. Temperature stability: ≤0.002%/℃
 
10. Working current: ≤16mA
 
11. Operating temperature :T1: -20 ~ +55℃, T2: -40 ~ +80℃, T3: -50 ~ +125℃
 
12. Rod material: 0Cr18Ni9 (304) 316 stainless steel (special custom)
 
13. Electronic bin shell material: anodized alumina (special custom)
 
14. Lead mode: high-temperature resistant twisted-pair shielded cable (default length: 1M, can also be provided according to user requirements)
 
15. Protection grade of enclosure: IP65
 

 


 

Connection method


Before connecting cables, ensure that the power supply meets the requirement of +24VDC and that the output power of the power supply is greater than or equal to 95mA for each sensor. If the power supply cannot meet the requirements, replace the power supply to ensure the normal operation of the sensor.

 


Analog signal output wiring mode of MTL5 magnetostrictive displacement sensor:

 

1. Connection mode of direct outlet of waterproof connector:

The sensor has five contacts: positive power supply (brown), negative power supply (black), positive signal output (blue), negative signal output (white), shell ground (shielded line)

 

2. Wiring mode of aviation plug:

The sensor has five contacts: (1) positive power supply (brown), (2) negative power supply (black), (3) positive signal output (blue), (4) negative signal output (white), (5) shell (shielded line)

 

3. Connection mode of Hersman plug:

The sensor has four contacts: (1) positive power supply (brown), (2) positive signal output (blue), (3) negative power supply (black, white) E, shell ground (shielded line)

 

 


Installation Dimension


尺寸.png

Model Selection:

 

英文选型.jpg



  • Application