TEL:

180 3818 6775

Announcement:

Product

江苏Sensors

more+

Linear Position Sensor

more+

江苏KTC1/LWHPull Rod Linear Displacement Sensor 江苏KTF Slider Displacement Sensor 江苏KTF1 Slider Displacement Sensor 江苏KTR11/12,KTR2 Spring Self-return Position Potentiometer 江苏KTM Miniature Pull Rod Displacement Sensor 江苏KTC2 Pull Rod Linear Displacement Sensor 江苏KPC1H Hersman Plug out Pull-rod Resistance 江苏KPC1 Articulated Electronic Ruler 江苏KPM23 Small Articulated Resistance Sensor 江苏KPM22 Small Articulated Resistance Sensor 江苏KPM18 Small Articulated Resistance Sensor 江苏KPM16 Shock Travel Sensor 江苏KPM12 Shock Travel Sensor 江苏KPM12R1/KPM12R2 Self-reset Resistance Sensor 江苏WY-01 Resistive Displacement Sensor 江苏WDL Rod Type Displacement Sensor 江苏KSE Pull Rod Displacement Sensor 江苏KPF Flange Displacement Sensor 江苏KFM Micro Slider Type Resistance Sensor 江苏KSP Circular Tube Miniature Self-reset 江苏KSC Square Tube Miniature Self-reset Displacement sensor 江苏KS8X Micro Self-resetting Displacement Sensor 江苏KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 江苏KST Self resetting displacement sensor 江苏KSD Linear Position Sensor 13FLP 江苏KPFZ Flange-mounted self-resetting resistance ruler 江苏LEP displacement sensorwith Waterproof and dustproof 江苏KEP Brushless Sensor with Waterproof and Dustproof 江苏LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 江苏KPM9 Mini Type Pull Rod Displacement Sensor 江苏KSE Rod type displacement sensor 江苏KSF Micro Slide Type Displacement Sensor 江苏KSN Self-resetting Displacement Sensor
Rope/wire displacement sensor

more+

江苏MPS-XXXS Pull Wire Displacement Sensor 江苏MPS-XXS Pull Wire Displacement Sensor 江苏MPS-XS Pull Wire Displacement Sensor 江苏MPS-S Pull Wire Displacement Sensor 江苏MPS-M Pull Wire Displacement Sensor 江苏MPS-L Pull Wire Displacement Sensor 江苏MPS-XL Pull Wire Displacement Sensor 江苏MPSFS2-S Waterproof Absolute Wire Rope Sensor 江苏MPSFS2-M Waterproof Absolute Wire Rope Sensor 江苏MPSFS2-L Waterproof Absolute Wire Rope Sensor 江苏MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 江苏MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 江苏MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 江苏MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 江苏MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 江苏MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 江苏MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 江苏MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 江苏MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 江苏SM-S Pull Wire Displacement Sensor 江苏SM-M Pull Wire Displacement Sensor 江苏WEP-S Pull Wire Displacement Sensor 江苏WEP-M Pull Wire Displacement Sensor 江苏WS-S Pull Wire Displacement Sensor 江苏MDS-S Pull Wire Displacement Sensor 江苏MPS-XS Magnetic Mounting Rope Displacement Sensor 江苏MPS-L Magnetic Draw Wire Displacement Sensor 江苏MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 江苏MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 江苏MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor
江苏Fully Automatic Lubricating Oil Pump

more+

江苏Electric Automatic Oil Pump / Manual Oil Pump

more+

江苏MIRAN MR-2202-2(2L) Thin Oil Lubrication Pump Controlled by PLC Type 江苏MIRAN MR-2232-2(2L) Self-control Electric Oil Lubrication Pump 江苏MIRAN MR-2202-3(3L) Thin Oil Electric Lubrication Pump 江苏MIRAN MR-2232-3(3L)Self-control Electric Oil Lubrication Pump 江苏MIRAN MRG-2202(4L) Asynchronous Dynamo Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 江苏MIRAN MRG-2232(4L) Asynchronous Dynamo Grease and Thin Oil Lubrication Intergrated Pump 江苏MIRAN MRG-3202(5L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 江苏MGH-1205-100T Semi-automatic Butter Lubrication Pump 江苏MIRAN MRG-3205(5L) Grease and Thin Oil Intergratd Pump by PLC Type 江苏MIRAN MRG-3232(5L)Grease and Thin Oil Lubrication Intergrated Pump 江苏MRG-3202(3L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 江苏MIRAN MRG-3235(5L) Grease and Thin Oil Lubrication Electric Intergrated Pump 江苏MRG-3232(3L) Self-control Grease and Thin Oil Lubrication Pump 江苏MIRAN MRG-5202(3L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 江苏MRG-5232-41 Self-control Grease and Thin Oil Lubrication Pump 江苏MIRAN MRG-5202-41 (4L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 江苏MRG-5202(5L) Self-control Grease and Thin Oil Lubrication Pump with PLC Type 江苏MRG-5232(5L) Self-control Grease and Thin Oil Lubrication Pump 江苏MRH-1202-100T Semi-automatic Grease Lubrication Pump 江苏MRH-1232-100TB Automatical Grease Lubrication Pump 江苏MGH-1202-100T Semi-automatic Butter Lubrication Pump 江苏MGH-1232-100TB Self-control Butter Pump
Your current location is:Home>>江苏Product>>江苏Sensors>>江苏Transfer module and digital display instrument

江苏XSK Display controller digital display (single channel)

  • Product classification:Transfer module and digital display instrument
  • Number of views:1308
  • QR code:
  • Release time:2023-11-15
  • Overview

XSK Digital Display Instrument

0.2 level accuracy, measurement and control speed can be set to 10 or 40 times per second,display range -1999~9999.
Dual four-digit digital tube display (main display + second display), of which the second display can display engineering quantity units, alarm values and other information.
Universal input, selected by setting up.
Optional 1 to 4 points alarm output. 7 basic alarm modes and 4 standby alarm modes: upper limit of standby, lower limit of standby, upper limit of standby deviation, and lower limit of standby deviation. (Standby alarm mode: means that when the instrument is powered on, it does not alarm when the measured value is in the output range. When the measured value enters the non-output range, a standby condition is established, and then the alarm is normal).
10-section polyline correction function.
1 point external switch input, used for clearing.
 Peak and valley value acquisition function.
Communication and transmission are optional.

content

Code description

XSK-

Universal analog input, 0.2 level display accuracy; measurement and control speed can be set to 10 or 40 times per second

Dimension

AH

160×80×125      Hole Size:152×76      (Note①)

AS

80×160×125       Hole Size:152×76   (Note①)

 

B

96×96×76       Hole Size:92×92      (Note②)

 

CH

96×48×82       Hole Size:92×45      (Note③)

 

CS

48×96×82       Hole Size:92×45      (Note③)

 

D

72×72×75       Hole Size:68×68      (Note④)

 

E

48×48×88       Hole Size:45.5×45.5  (Note⑤)

 

Panel specifications


Dual 4-digit LED display

Contact input (optional)

K

1 point external switch input for zeroing.(When AH and CH select K, communication and transmission can only choose one option; E size does not support K option)

Alarm(option)(250V AC/3A,resistive load)

A

T1~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

B

 

T1~T2

1~2 point relay output, are normally open and closed double contacts

 

T3~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

C

T1~T2

The output of 1~2 point alarm relay is normally open and closed double contacts

T3

The output of 3 alarm relay is single open contact

T3R

The output of the 3-point alarm relay is normally open and closed double contacts

T4

4 points alarm relay output, the first 3 points are single normally open contact, the fourth point is normally open normally closed double contact

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

D

T1~T2

1~2 point alarm relay output, 1 often open and close double contact; 1 often open contact

T3

3 points of alarm relay output, 1 point is normally open and normally closed double contact, and another 2 points are single and normally open contact

O1~O3

1-3 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

E

T1~T2

1~2 point alarm relay output, 1 point often open often closed contact, the other point is normally open contact

O1~O2

1-2 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

Transmitting (optional)

(resolution: 1/3000; load capacity: 600Ω)

A1

Current output(4-20)mA、(0-10)mA、(0-20)mA

A2

Voltage output(1-5)V、(0-5)V

A3

Voltage output(0-10)V

A4

Voltage output(-5V-+5V)

A5

Voltage output(-10V-+10V)

External power supply (optional)

B1

24V±5% 50mA below

B2

12V±5% 50mA below

B3

10V±5% 50mA below

Communication (option) (the communication protocol is optional through the instrument parameters: Modbus-RTU or TC-ASCII protocol)

S1

The RS232 interface(only AH AS B size)

S2

The RS485 interface

Power Specifications

V0

100-240V AC 50/60 Hz

V1

10-24VAC 50/60Hz;10-24VDC 

Note : A size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note : B size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note :C size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3R or T4 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected one of the two, and communication can only select RS485 mode (i.e. S2)

Note : D size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected from one of the two, and communication can only select RS485 mode (i.e. S2)

Note : E size instrument

You can choose two out of three for 1-point switching input, transmission output and communication functions (communication only supports RS485 at this time)

When 2-point alarm output is selected2, external power supply cannot be selected; 1-point switching input, transmission output and communication functions can be selected two out of three (communication only supports RS485 at this time)



  • Application