TEL:

180 3818 6775

Announcement:

Product

惠州Sensors

more+

Linear Position Sensor

more+

惠州KTC1/LWHPull Rod Linear Displacement Sensor 惠州KTF Slider Displacement Sensor 惠州KTF1 Slider Displacement Sensor 惠州KTR11/12,KTR2 Spring Self-return Position Potentiometer 惠州KTM Miniature Pull Rod Displacement Sensor 惠州KTC2 Pull Rod Linear Displacement Sensor 惠州KPC1H Hersman Plug out Pull-rod Resistance 惠州KPC1 Articulated Electronic Ruler 惠州KPM23 Small Articulated Resistance Sensor 惠州KPM22 Small Articulated Resistance Sensor 惠州KPM18 Small Articulated Resistance Sensor 惠州KPM16 Shock Travel Sensor 惠州KPM12 Shock Travel Sensor 惠州KPM12R1/KPM12R2 Self-reset Resistance Sensor 惠州WY-01 Resistive Displacement Sensor 惠州WDL Rod Type Displacement Sensor 惠州KSE Pull Rod Displacement Sensor 惠州KPF Flange Displacement Sensor 惠州KFM Micro Slider Type Resistance Sensor 惠州KSP Circular Tube Miniature Self-reset 惠州KSC Square Tube Miniature Self-reset Displacement sensor 惠州KS8X Micro Self-resetting Displacement Sensor 惠州KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 惠州KST Self resetting displacement sensor 惠州KSD Linear Position Sensor 13FLP 惠州KPFZ Flange-mounted self-resetting resistance ruler 惠州LEP displacement sensorwith Waterproof and dustproof 惠州KEP Brushless Sensor with Waterproof and Dustproof 惠州LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 惠州KPM9 Mini Type Pull Rod Displacement Sensor 惠州KSE Rod type displacement sensor 惠州KSF Micro Slide Type Displacement Sensor 惠州KSN Self-resetting Displacement Sensor
Rope/wire displacement sensor

more+

惠州MPS-XXXS Pull Wire Displacement Sensor 惠州MPS-XXS Pull Wire Displacement Sensor 惠州MPS-XS Pull Wire Displacement Sensor 惠州MPS-S Pull Wire Displacement Sensor 惠州MPS-M Pull Wire Displacement Sensor 惠州MPS-L Pull Wire Displacement Sensor 惠州MPS-XL Pull Wire Displacement Sensor 惠州MPSFS2-S Waterproof Absolute Wire Rope Sensor 惠州MPSFS2-M Waterproof Absolute Wire Rope Sensor 惠州MPSFS2-L Waterproof Absolute Wire Rope Sensor 惠州MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 惠州MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 惠州MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 惠州MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 惠州MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 惠州MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 惠州MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 惠州MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 惠州MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 惠州SM-S Pull Wire Displacement Sensor 惠州SM-M Pull Wire Displacement Sensor 惠州WEP-S Pull Wire Displacement Sensor 惠州WEP-M Pull Wire Displacement Sensor 惠州WS-S Pull Wire Displacement Sensor 惠州MDS-S Pull Wire Displacement Sensor 惠州MPS-XS Magnetic Mounting Rope Displacement Sensor 惠州MPS-L Magnetic Draw Wire Displacement Sensor 惠州MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 惠州MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 惠州MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor
惠州Fully Automatic Lubricating Oil Pump

more+

惠州Electric Automatic Oil Pump / Manual Oil Pump

more+

惠州MIRAN MR-2202-2(2L) Thin Oil Lubrication Pump Controlled by PLC Type 惠州MIRAN MR-2232-2(2L) Self-control Electric Oil Lubrication Pump 惠州MIRAN MR-2202-3(3L) Thin Oil Electric Lubrication Pump 惠州MIRAN MR-2232-3(3L)Self-control Electric Oil Lubrication Pump 惠州MIRAN MRG-2202(4L) Asynchronous Dynamo Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 惠州MIRAN MRG-2232(4L) Asynchronous Dynamo Grease and Thin Oil Lubrication Intergrated Pump 惠州MIRAN MRG-3202(5L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 惠州MGH-1205-100T Semi-automatic Butter Lubrication Pump 惠州MIRAN MRG-3205(5L) Grease and Thin Oil Intergratd Pump by PLC Type 惠州MIRAN MRG-3232(5L)Grease and Thin Oil Lubrication Intergrated Pump 惠州MRG-3202(3L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 惠州MIRAN MRG-3235(5L) Grease and Thin Oil Lubrication Electric Intergrated Pump 惠州MRG-3232(3L) Self-control Grease and Thin Oil Lubrication Pump 惠州MIRAN MRG-5202(3L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 惠州MRG-5232-41 Self-control Grease and Thin Oil Lubrication Pump 惠州MIRAN MRG-5202-41 (4L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 惠州MRG-5202(5L) Self-control Grease and Thin Oil Lubrication Pump with PLC Type 惠州MRG-5232(5L) Self-control Grease and Thin Oil Lubrication Pump 惠州MRH-1202-100T Semi-automatic Grease Lubrication Pump 惠州MRH-1232-100TB Automatical Grease Lubrication Pump 惠州MGH-1202-100T Semi-automatic Butter Lubrication Pump 惠州MGH-1232-100TB Self-control Butter Pump
Your current location is:Home>>惠州Product>>惠州Sensors>>惠州Transfer module and digital display instrument

惠州XSEW Display controller digital display (single channel)

  • Product classification:Transfer module and digital display instrument
  • Number of views:1061
  • QR code:
  • Release time:2023-11-15
  • Overview

XSEW Digital Display Instrument

0.05 level precision, measurement and control speed of 10 ~400 times per second can be set
Display range-99999~99999
Analog quantity is universal input, selected by setting
The 1-4-point alarm output is optional. It includes seven basic alarm methods, including measurement upper limit, measurement lower limit, deviation upper limit, deviation upper limit, deviation absolute value lower limit, fault alarm and four standby alarm methods.(Standby alarm mode: when the measured value is in the output interval, when the measured value enters the non-output interval, then the normal alarm)
Higher degree of standardization, rich functions. Including: input signal fault processing, measurement value clearance, peak, valley value acquisition, 10 section broken line correction and other functions
Optional transmission, communication

content

Code description

XSEW-

0.05 level measurement accuracy;Measurement and control speed is 10 times per second

Dimension

AH

160×80×125      Hole Size:152×76 (Note①)

CH

96×48×82       Hole Size:92×45 (Note②)

 

Panel specifications


Single 6-digit LED display

 Alarm(option)(250V AC/3A,resistive load)

AH

T1~T4

1~4 point relay output, are normally open and closed double contacts

 

01~04

Alarm is OC door output (voltage should be less than 40VDC and current should be less than 40 mA)

CH

T1~T2

1~2 point relay output, are normally open and closed double contacts

01~02

Alarm is OC door output (voltage should be less than 40VDC and current should be less than 40 mA)

T3

3 point relay output is a single open contact.

03

Alarm is OC door output (voltage should be less than 40VDC and current should be less than 40 mA)

Contact input (optional)

K

1 point external switch quantity input for reset

Transmitting (optional)

(resolution: 1/3000; load capacity: 600Ω)(Suitable for the measurement and control speed of 200 times per second and above the transmission speed)

A1

Current output(4-20)mA、(0-10)mA、(0-20)mA

A2

Voltage output(1-5)V、(0-5)V

A3

Voltage output(0-10)V

A4

 

Voltage output (-5V-+5V)

A5

Voltage output (-10V-10V)

Quick delivery (optional)

F

Suitable for the measurement and control speed of 200 times per second and above the transmission speed

External power supply (optional)

B1

24V±5% 50mA below

B2

12V±5% 50mA below

B3

10V±5% 50mA below

Communication (option)

(Optional via instrument parameters: Modbus-RTU or TC-ASCII communication protocol)

S1

RS232 interface (only AH size)

S2

RS485 interface

Power Specifications

V0

100-240V AC 50/60 Hz

V1

10-24VAC 50/60Hz;10-24VDC 

Note①:A size instrument

When selecting 1-point switching input, the instrument’s transmission output and communication functions can only be selected from one of the two.
Note②:C size instrument
When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (communication only supports RS485 at this time)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)


单通道XSEW显示控制器数显表安装尺寸

Ⅵ、Single channel XSEW display controller Digit Instrument

Installation precautions
1 )Please avoid the installation in the following places: 

1.1:Because of the drastic temperature change, it may be exposed places
1.2:Places where corrosive gases and combustible gases are produced
1.3:Where direct vibration or may impact the product
1.4:Dust, salt, metal powder more places
1.5:Clutter interference, prone to static electricity, magnetic field, noise place

1.6: Air conditioning or heating air flow blowing directly to the place

1.7:  A place where the sunlight shines directly

1.8: Due to thermal radiation and other possible thermal accumulation of places

(2)  When installing, please consider the following points:
2.1:In order not to hinder heat dissipation, do not block the surroundings of this product, do not block the ventilation openings, and leave sufficient ventilation space.
2.2:Considering wiring and maintenance, please ensure there is more than 50mm of space above and below the instrument.
2.3:Please installing installation directly above the high heat meter (heater, transformer, semiconductor operator, high power resistance).
2.4:If the ambient temperature is above 50℃, please use a forced fan or a cooler, but do not let the cooling air blow directly to the instrument.
2.5:In order to improve noise resistance and safety, please keep away from high pressure machine, power line, power machine for installation.


Ⅵ:Single channel XSEW display controller digit instrument wiring precautions

In order to avoid the influence of noise interference, please keep the input signal line away from the instrument power line, power power line and load line.

Ensure that the instrument power supply is not affected by the noise of the power supply when wiring. Where noise is susceptible, use a noise filter.

- Please twist the wire material into a twist shape. The shorter the pitch of the twist, the better the noise defense effect.
- Be sure to install the noise filter on the ground disk surface, and minimize the wiring between the output side of the noise filter and the power terminal.
- Please do not install the fuse, switch, etc. on the output side of the noise filter, otherwise the effect of the filter will be reduced.

Note: There is no fuse inside this instrument. For fuse-required occasions, please set up separately: recommended fuse specifications:

- Rated voltage 250V, time delay fuse of rated current 1A

-  Please use the power supply that meets the power supply specification.

-  Please avoid mixing the interference in the measurement circuit

- The measurement circuit is separated from the power cord (power circuit) or the ground circuit.
- For the interference of static electricity, the use of shielding line effect is good.

- To prevent misoperation, please do not attach any wires to the unused terminals.


  • Application