Paired with resistance scale, eddy current displacement sensor, etc. 0.05 level accuracy, measurement and control speed 10 times per second. Display range -19999~45000. Panel keys and switch input zero setting function. 8-segment polyline correction function. Optional 1 to 4 alarm output points. There are five basic alarm modes and five standby alarm modes corresponding to the five basic alarm modes. (Standby alarm mode: means that when the instrument is powered on, it will not alarm even if it is in the alarm area. When the measured value enters the non-alarm area, the standby condition will be established, and then it will alarm normally). 4 optional external power supplies. Optional communication, transmission and printing functions.
■ Connecting with resistance scale, eddy current displacement sensor, etc.
■ 0.2 level accuracy, measuring and controlling speed can be reached at 10 times per second. Display range -1999~9999
■ Panel button and digital input zero function
■ 8-band polyline correction function
■ Optional can be choosen from 1 to 4 alarm output. Including the upper limit of measurement value, the lower limit of measurement value, the upper limit of deviation, the lower limit of deviation, the absolute value of deviation, five basic alarm modes and five standby alarm modes corresponding to five basic alarm modes
(Standby alarm mode: When the instrument is powered on, it will not alarm even if it is in the alarm area. When the measured value enters the non-alarm area, the standby condition is established, and then the alarm is normal.)
■ 4 optional external power supplies
■ Optional communication, transmission and printing functions.
content | code description | |||||||||||
XSAE- | 0.05 level measurement accuracy; 10 times per second measurement and control speed | |||||||||||
Diemnsion | AH | 160×80×125 Hole Size:152×76 | ||||||||||
CH | 96×48×112 Hole Size:92×45 | |||||||||||
Panel specification | 5 Digit LED | |||||||||||
Signal input(Other input signals, instructions when ordering) | I | DC(4-20)mA、(0-10)mA、(0-20)mA | ||||||||||
V | DC Voltage(0-5)V、(1-5)V | |||||||||||
W | Potentiometer(500Ω~10kΩ) | |||||||||||
Contact input (optional) | K | 1 point external switch input for zeroing. | ||||||||||
Alarm(optional) | T1~4 | T3、T4 limit AH (250V AC/3A,Resistance load) | ||||||||||
Transmitting (optional) (resolution: 1/3000; load capacity: 600Ω) | A1 | Current output(4-20)mA、(0-10)mA、(0-20)mA | ||||||||||
A2 | Voltage output(1-5)V、(0-5)V | |||||||||||
A3 | Voltage output(0-10)V | |||||||||||
External power supply (optional) (No external power supply is required when the input signal is W (potentiometer) | B1 | 24V±5% 50mA below | ||||||||||
B1G | 24V±5% 100mA below | |||||||||||
B2 | 12V±5% 50mA below | |||||||||||
B2G | 12V±5% 100mA below | |||||||||||
Communication (optional) (communication rate: 2400, 4800, 9600, 19200) (Address: 0-99) | S1 | TC ASCII Protocol RS232 | ||||||||||
S2 | TC ASCII Protocol RS485 | |||||||||||
M1 | Modbus-RTU Protocol RS232 | |||||||||||
M2 | Modbus-RTU Protocol RS485 | |||||||||||
Print interface (optional) | P | |||||||||||
Power Specifications | V0 | 100-240V AC 50/60 Hz | ||||||||||
V1 | 10-24V AC 50/60 Hz;10-24V DC(limit CH) |