Ⅰ、MR-50 magnetic ating measurement system
Summary:
This product is a magnetic grating measurement system, in which MR is the reading head and MS is the magnetic scale. They work based on the principle of magnetic induction. When the MR read head makes linear motion in the magnetic field space of the MS magnetic scale, the read head will output a standard position pulse in real time based on the relevant displacement of the movement. This product is mainly used in woodworking, stone processing, sawing, metal cutting, textile, printing, packaging, plastic processing, automation systems, cutting equipment, electronic assembly equipment, measurement/inspection equipment, etc.
Pure German imported magnetic tape material:
Features:
Non-contact ,high speed measurement
High resolution
Strong resistance to dirt and oil
Easy to install
Excellent economy
Ⅱ、Size selection:
Ⅲ、Technical parameter:
Read head | MR-50 |
Magnetic ruler | MS-50 |
Resolution | 5μm |
Working voltage | 5 ~ 30V DC |
Output signal | A / B / Z |
Precision(20℃) | ±50μm/m |
Repeatability Precision | Max. ±1 Unit resolution(one-way) |
Measuring Range | Customized |
Installation Gap | Max. 2.5mm |
Move Speed | Max. 25m/s |
No-load Current | Max. 30mA |
Output current | Max. 50mA(Each signal) |
Operating temperature | -20℃ ~ +85℃ |
Protection | IP68(IEC60529:2001) |
Linear Expansivity | ~ 17 × 10-6/K |
Frequency | 1.25MHZ |
AB signal Number of 1mm pulses | 50 PCS (each 0.02mm,1 pulse) |
The number of pulses per 5mm of Z signal | A pulse |
Anti-interference(EMC) | Electrostatic discharge(ESD: EN61000-4-2);Radio-frequency(EN61000-4-3, EN61000-4-6); Electrical fast transient(EFT: EN61000-4-4); Surge(EN61000-4-5); Power frequency magnetic field(EN61000-4-8); |
Ⅳ、External size:(unit mm)
Ⅴ、Installation requirements:
Ⅵ、Output definition:
+VCC | Red |
0V | Black |
A | Yellow |
B | White |
Z | Green |
●The AB signal is one pulse per 0.02mm.
Indicator light:
Green:in working order
Red green: magnetic signal is too weak to be checked
The indicator light can only indicate whether the working power supply and magnetic scale signal are normal, and cannot guarantee the measurement accuracy after installation. If you need to improve the accuracy, please try to move the reading head as close to the magnetic scale as possible during installation.
Ⅶ、Magnetic ruler installation:
When installing using the mounting slot method, the dimensions of the pre-opened mounting slot are shown in the figure below.
The magnetic ruler can be installed horizontally and side-mounted, but try to avoid installing it upside down, see the picture below.