TEL:

180 3818 6775

Announcement:

Product

德宏Sensors

more+

Linear Position Sensor

more+

德宏KTC1/LWHPull Rod Linear Displacement Sensor 德宏KTF Slider Displacement Sensor 德宏KTF1 Slider Displacement Sensor 德宏KTR11/12,KTR2 Spring Self-return Position Potentiometer 德宏KTM Miniature Pull Rod Displacement Sensor 德宏KTC2 Pull Rod Linear Displacement Sensor 德宏KPC1H Hersman Plug out Pull-rod Resistance 德宏KPC1 Articulated Electronic Ruler 德宏KPM23 Small Articulated Resistance Sensor 德宏KPM22 Small Articulated Resistance Sensor 德宏KPM18 Small Articulated Resistance Sensor 德宏KPM16 Shock Travel Sensor 德宏KPM12 Shock Travel Sensor 德宏KPM12R1/KPM12R2 Self-reset Resistance Sensor 德宏WY-01 Resistive Displacement Sensor 德宏WDL Rod Type Displacement Sensor 德宏KSE Pull Rod Displacement Sensor 德宏KPF Flange Displacement Sensor 德宏KFM Micro Slider Type Resistance Sensor 德宏KSP Circular Tube Miniature Self-reset 德宏KSC Square Tube Miniature Self-reset Displacement sensor 德宏KSF Micro Slide Type Displacement Sensor 德宏KS8X Micro Self-resetting Displacement Sensor 德宏KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 德宏KST Self resetting displacement sensor 德宏KSD Linear Position Sensor 13FLP 德宏KPFZ Flange-mounted self-resetting resistance ruler 德宏LEP displacement sensorwith Waterproof and dustproof 德宏KEP Brushless Sensor with Waterproof and Dustproof 德宏LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 德宏KPM9 Mini Type Pull Rod Displacement Sensor 德宏KSE Rod type displacement sensor 德宏KSN Self-resetting Displacement Sensor
Rope/wire displacement sensor

more+

德宏MPS-XXXS Pull Wire Displacement Sensor 德宏MPS-XXS Pull Wire Displacement Sensor 德宏MPS-XS Pull Wire Displacement Sensor 德宏MPS-S Pull Wire Displacement Sensor 德宏MPS-M Pull Wire Displacement Sensor 德宏MPS-L Pull Wire Displacement Sensor 德宏MPS-XL Pull Wire Displacement Sensor 德宏MPSFS2-S Waterproof Absolute Wire Rope Sensor 德宏MPSFS2-M Waterproof Absolute Wire Rope Sensor 德宏MPSFS2-L Waterproof Absolute Wire Rope Sensor 德宏MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 德宏MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 德宏MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 德宏MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 德宏MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 德宏MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 德宏MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 德宏MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 德宏MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 德宏SM-S Pull Wire Displacement Sensor 德宏SM-M Pull Wire Displacement Sensor 德宏WEP-S Pull Wire Displacement Sensor 德宏WEP-M Pull Wire Displacement Sensor 德宏WS-S Pull Wire Displacement Sensor 德宏MDS-S Pull Wire Displacement Sensor 德宏MPS-XS Magnetic Mounting Rope Displacement Sensor 德宏MPS-L Magnetic Draw Wire Displacement Sensor 德宏MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 德宏MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 德宏MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor
德宏Fully Automatic Lubricating Oil Pump

more+

Your current location is:Home>>德宏Product>>德宏Sensors>>Eddy Current Displacement Sensor

德宏ML33-RG High temperature resistant type eddy current displacement sensor

  • Product classification:Eddy Current Displacement Sensor
  • Number of views:26
  • QR code:
  • Release time:2024-10-28
  • Overview

I. Principle of ML33-RG high temperature resistant type eddy current displacement sensor:

Eddy current sensor systems work on the eddy current effect, which is an inductive measuring principle. The eddy current effect originates from the energy of an oscillating circuit. The eddy currents need to be formed in a conductive material. By introducing an alternating current into the coil inside the sensor probe, a magnetic field is formed around the probe coil. If a conductor is placed into this magnetic field, eddy currents are excited in the conductor according to Faraday's law of electromagnetic induction. According to Franz's law, the magnetic field of the eddy currents is in the opposite direction of the magnetic field of the coil, and this changes the impedance of the coil inside the probe. This change in impedance is directly related to the distance from the coil to the object being measured. After the sensor probe is connected to the controller, the controller can obtain the change in voltage value from the sensor probe and use this as a basis for calculating the corresponding distance value, the eddy current measurement principle can measure all conductive materials.
Since eddy currents can penetrate insulators, even metallic materials covered with insulators can be used as measurement objects for eddy current sensors. The unique coil winding design enables the sensor to operate in high-temperature measurement environments while maintaining a compact form factor.

2. ML33-RG high temperature resistant type eddy current displacement sensor application areas:By measuring the relative position of the metal body to be measured and the probe end, eddy current displacement sensor sensing and processing into the corresponding electrical signal output. The sensor can work reliably for a long time, high sensitivity, strong anti-interference ability, non-contact measurement, fast response speed is not subject to the influence of oil and water and other media, in the large-scale rotating machinery, such as shaft displacement, shaft vibration, shaft speed and other parameters of long-term real-time monitoring is widely used, and has been extended to the satellite launch, material identification, weighing measurement, metal plate thickness measurement, material deformation and other application areas.
3. ML33-RG high temperature resistant type eddy current displacement sensor technical parameters:

Measure range

12.5mm

20mm

25mm

40mm

Probe diameter

Φ30mm

Φ40mm

Φ50mm

Φ60mm

Linearity error

≤±1%FS

≤±1%FS

≤±1%FS

≤±2%FS

Repeatability

2um

2~4um

2~4um

2~5um

Frequency response

0~100Hz

Output signal

RS485

Resolution

16bit

Supply voltage

+9~36VDC

Working current

<70mA

Probe temperature compensation range

0℃~+180℃

Temperature drift error

≤±1mm

Operating temperature

probe 0℃~+180℃,proximitor 0℃~+60℃

Protection grade

probe IP67,proximitor IP65

Probe cable 

standard 2mcan be customized

Feed cable

standard 2mcan be customized

4.ML33-RG high temperature resistant type eddy current displacement sensor wiring:
The sensor has five contacts: positive power (brown), power ground (black), RS485A (blue), RS485B (white), and case ground (shielded).
5. ML33-RG high temperature resistant type eddy current displacement sensor installation dimensions:
The ML33 sensor system consists of probes, proximitor, cables, and accessories.

1. Eddy current probe:

Usually the probe consists of a coil, head, shell, high-frequency cable, high-frequency connector. In the production process, the probe head body is generally used in high temperature PPS engineering plastics, through the ‘secondary injection’ moulding will be sealed coil. So that the probe can work reliably in harsh environments. As the coil diameter of the head body to determine the linear range of the sensor system, so we usually use the external diameter of the head body to classify and characterise the various types of probes, in general, the linear range of the sensor system is roughly 1/2 to 1/4 times the diameter of the head of the probe.ML33 series sensors probes are shown in the table:


Range

Probe diameter

Probe length

shell length

Installation type

Thread specification

12.5mm

Φ30mm

26mm

40mm

Reverse-mounting

M14X1.5

20mm

Φ40mm

33mm

40mm

Reverse-mounting

M14X1.5

25mm

Φ50mm

42mm

50mm

Reverse-mounting

M18X1.5

40mm

Φ60mm

47mm

50mm

Reverse-mounting

M18X1.5

Probe housings are used to connect and secure the probe head and are used as a clamping structure when the probe is mounted. The housings are generally made of 304 stainless steel with standard threads and locking nuts. In order to adapt to different applications and installations, probe housings are available in different forms and with different threads and dimensions.

2. Proximitor:

The proximitor is the signal processing centre of the whole sensor system. On the one hand, the preamplifier for the probe coil to provide high-frequency AC excitation current to make the probe work; on the other hand, the preamplifier through a special circuit senses the probe head body and the head body in front of the metal conductor of the gap changes, through the preamplifier processing, resulting in the gap with the linear changes in the output signal.

ML33-RG series proximitor outline dimensional drawing  

Probe selection rulers
电涡流选型.jpg

●  A □□:Probe range code selection

 

▼   Probe code classification 

 

Code

12

20

25

40

Measuring range

12.5mm

20mm

25mm

40mm

  

●  B□□ :No thread length option

  The threaded part of the probe is to facilitate installation, reduce invalid thread length, and make screwing bolts faster

  

▼Metric threaded probe

Minimum unthreaded length 0mm

0

0

Maximum unthreaded length 250 mm

2

5

Increase by  10 mm

0

1

● C □□ Shell length selection

The length of the probe shell depends on the use of the site, in order to ensure the measurement accuracy, avoid the vibration of the probe rod to bring measurement interference, it is recommended not to use more than 300mm long shell length; When necessary, a mounting attachment for strengthening the probe rod should be attached.

 

▼Metric shell length

Minimum shell length 20mm

0

2

Maximum shell length 250 mm

2

5

Increase by  10 mm

0

1

● C □□ Shell length selection

The length of the probe shell depends on the use of the site, in order to ensure the measurement accuracy, avoid the vibration of the probe rod to bring measurement interference, it is recommended not to use more than 300mm long shell length; When necessary, a mounting attachment for strengthening the probe rod should be attached.

 

▼Metric shell length

Minimum shell length 20mm

0

2

Maximum shell length 250 mm

2

5

Increase by  10 mm

0

1

 

6. Installation and use:

Probe installation

When mounting the probes, you should pay attention to the following issues.

□ Distance between each probe of the port            □Distance between the port probe and the mounting surface

□Selection of mounting bracket                               □Mouth probe mounting clearance

□Installation of the cable with the probe                 □Sealing and insulation of the cable adapter of the port

□Corrosion resistance of the probe                          □High pressure environment of the probe

● Distance between probes
When the current is passed through the coil of the probe head, an alternating magnetic field will be generated around the head, so when installing the two probes, it should be noted that the installation distance between the two probes should not be too close, otherwise the two probes will interfere with each other through the magnetic field (as shown in the following figure of the distance between the probes), and the output signal iterated on the two probes of the differential signal, resulting in a distortion of the results of the measurements, which is a case we call the neighbourhood of the interference. Factors related to the elimination of neighbouring interference are: the shape of the measured body, the head diameter of the probes, and the mounting method. Typically, the * minimum distance between the probes is shown in the table below.


  • Application