TEL:

180 3818 6775

Announcement:

Product

大兴安岭Sensors

more+

Linear Position Sensor

more+

大兴安岭KTC1/LWHPull Rod Linear Displacement Sensor 大兴安岭KTF Slider Displacement Sensor 大兴安岭KTF1 Slider Displacement Sensor 大兴安岭KTR11/12,KTR2 Spring Self-return Position Potentiometer 大兴安岭KTM Miniature Pull Rod Displacement Sensor 大兴安岭KTC2 Pull Rod Linear Displacement Sensor 大兴安岭KPC1H Hersman Plug out Pull-rod Resistance 大兴安岭KPC1 Articulated Electronic Ruler 大兴安岭KPM23 Small Articulated Resistance Sensor 大兴安岭KPM22 Small Articulated Resistance Sensor 大兴安岭KPM18 Small Articulated Resistance Sensor 大兴安岭KPM16 Shock Travel Sensor 大兴安岭KPM12 Shock Travel Sensor 大兴安岭KPM12R1/KPM12R2 Self-reset Resistance Sensor 大兴安岭WY-01 Resistive Displacement Sensor 大兴安岭WDL Rod Type Displacement Sensor 大兴安岭KSE Pull Rod Displacement Sensor 大兴安岭KPF Flange Displacement Sensor 大兴安岭KFM Micro Slider Type Resistance Sensor 大兴安岭KSP Circular Tube Miniature Self-reset 大兴安岭KSC Square Tube Miniature Self-reset Displacement sensor 大兴安岭KS8X Micro Self-resetting Displacement Sensor 大兴安岭KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 大兴安岭KST Self resetting displacement sensor 大兴安岭KSD Linear Position Sensor 13FLP 大兴安岭KPFZ Flange-mounted self-resetting resistance ruler 大兴安岭LEP displacement sensorwith Waterproof and dustproof 大兴安岭KEP Brushless Sensor with Waterproof and Dustproof 大兴安岭LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 大兴安岭KPM9 Mini Type Pull Rod Displacement Sensor 大兴安岭KSE Rod type displacement sensor 大兴安岭KSF Micro Slide Type Displacement Sensor 大兴安岭KSN Self-resetting Displacement Sensor
Rope/wire displacement sensor

more+

大兴安岭MPS-XXXS Pull Wire Displacement Sensor 大兴安岭MPS-XXS Pull Wire Displacement Sensor 大兴安岭MPS-XS Pull Wire Displacement Sensor 大兴安岭MPS-S Pull Wire Displacement Sensor 大兴安岭MPS-M Pull Wire Displacement Sensor 大兴安岭MPS-L Pull Wire Displacement Sensor 大兴安岭MPS-XL Pull Wire Displacement Sensor 大兴安岭MPSFS2-S Waterproof Absolute Wire Rope Sensor 大兴安岭MPSFS2-M Waterproof Absolute Wire Rope Sensor 大兴安岭MPSFS2-L Waterproof Absolute Wire Rope Sensor 大兴安岭MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 大兴安岭MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 大兴安岭MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 大兴安岭MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 大兴安岭MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 大兴安岭MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 大兴安岭MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 大兴安岭MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 大兴安岭MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 大兴安岭SM-S Pull Wire Displacement Sensor 大兴安岭SM-M Pull Wire Displacement Sensor 大兴安岭WEP-S Pull Wire Displacement Sensor 大兴安岭WEP-M Pull Wire Displacement Sensor 大兴安岭WS-S Pull Wire Displacement Sensor 大兴安岭MDS-S Pull Wire Displacement Sensor 大兴安岭MPS-XS Magnetic Mounting Rope Displacement Sensor 大兴安岭MPS-L Magnetic Draw Wire Displacement Sensor 大兴安岭MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 大兴安岭MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 大兴安岭MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor
大兴安岭Fully Automatic Lubricating Oil Pump

more+

大兴安岭Electric Automatic Oil Pump / Manual Oil Pump

more+

大兴安岭MIRAN MR-2202-2(2L) Thin Oil Lubrication Pump Controlled by PLC Type 大兴安岭MIRAN MR-2232-2(2L) Self-control Electric Oil Lubrication Pump 大兴安岭MIRAN MR-2202-3(3L) Thin Oil Electric Lubrication Pump 大兴安岭MIRAN MR-2232-3(3L)Self-control Electric Oil Lubrication Pump 大兴安岭MIRAN MRG-2202(4L) Asynchronous Dynamo Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 大兴安岭MIRAN MRG-2232(4L) Asynchronous Dynamo Grease and Thin Oil Lubrication Intergrated Pump 大兴安岭MIRAN MRG-3202(5L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 大兴安岭MGH-1205-100T Semi-automatic Butter Lubrication Pump 大兴安岭MIRAN MRG-3205(5L) Grease and Thin Oil Intergratd Pump by PLC Type 大兴安岭MIRAN MRG-3232(5L)Grease and Thin Oil Lubrication Intergrated Pump 大兴安岭MRG-3202(3L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 大兴安岭MIRAN MRG-3235(5L) Grease and Thin Oil Lubrication Electric Intergrated Pump 大兴安岭MRG-3232(3L) Self-control Grease and Thin Oil Lubrication Pump 大兴安岭MIRAN MRG-5202(3L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 大兴安岭MRG-5232-41 Self-control Grease and Thin Oil Lubrication Pump 大兴安岭MIRAN MRG-5202-41 (4L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 大兴安岭MRG-5202(5L) Self-control Grease and Thin Oil Lubrication Pump with PLC Type 大兴安岭MRG-5232(5L) Self-control Grease and Thin Oil Lubrication Pump 大兴安岭MRH-1202-100T Semi-automatic Grease Lubrication Pump 大兴安岭MRH-1232-100TB Automatical Grease Lubrication Pump 大兴安岭MGH-1202-100T Semi-automatic Butter Lubrication Pump 大兴安岭MGH-1232-100TB Self-control Butter Pump
Your current location is:Home>>大兴安岭Product>>Digital Indicator>>大兴安岭XSK Digital Display Instrument

大兴安岭XSK Digital Instrument

  • Product classification:XSK Digital Display Instrument
  • Number of views:1129
  • QR code:
  • Release time:2023-11-14
  • Overview

XSK Digital Display Instrument

0.2 level accuracy, measurement and control speed can be set to 10 or 40 times per second,display range -1999~9999.
Dual four-digit digital tube display (main display + second display), of which the second display can display engineering quantity units, alarm values and other information.
Universal input, selected by setting up.
Optional 1 to 4 points alarm output. 7 basic alarm modes and 4 standby alarm modes: upper limit of standby, lower limit of standby, upper limit of standby deviation, and lower limit of standby deviation. (Standby alarm mode: means that when the instrument is powered on, it does not alarm when the measured value is in the output range. When the measured value enters the non-output range, a standby condition is established, and then the alarm is normal).
10-section polyline correction function.
1 point external switch input, used for clearing.
 Peak and valley value acquisition function.
Communication and transmission are optional.

content

Code description

XSK-

Universal analog input, 0.2 level display accuracy; measurement and control speed can be set to 10 or 40 times per second

Dimension

AH

160×80×125      Hole Size:152×76      (Note①)

AS

80×160×125       Hole Size:152×76   (Note①)

 

B

96×96×76       Hole Size:92×92      (Note②)

 

CH

96×48×82       Hole Size:92×45      (Note③)

 

CS

48×96×82       Hole Size:92×45      (Note③)

 

D

72×72×75       Hole Size:68×68      (Note④)

 

E

48×48×88       Hole Size:45.5×45.5  (Note⑤)

 

Panel specifications


Dual 4-digit LED display

Contact input (optional)

K

1 point external switch input for zeroing.(When AH and CH select K, communication and transmission can only choose one option; E size does not support K option)

Alarm(option)(250V AC/3A,resistive load)

A

T1~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

B

 

T1~T2

1~2 point relay output, are normally open and closed double contacts

 

T3~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

C

T1~T2

The output of 1~2 point alarm relay is normally open and closed double contacts

T3

The output of 3 alarm relay is single open contact

T3R

The output of the 3-point alarm relay is normally open and closed double contacts

T4

4 points alarm relay output, the first 3 points are single normally open contact, the fourth point is normally open normally closed double contact

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

D

T1~T2

1~2 point alarm relay output, 1 often open and close double contact; 1 often open contact

T3

3 points of alarm relay output, 1 point is normally open and normally closed double contact, and another 2 points are single and normally open contact

O1~O3

1-3 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

E

T1~T2

1~2 point alarm relay output, 1 point often open often closed contact, the other point is normally open contact

O1~O2

1-2 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

Transmitting (optional)

(resolution: 1/3000; load capacity: 600Ω)

A1

Current output(4-20)mA、(0-10)mA、(0-20)mA

A2

Voltage output(1-5)V、(0-5)V

A3

Voltage output(0-10)V

A4

Voltage output(-5V-+5V)

A5

Voltage output(-10V-+10V)

External power supply (optional)

B1

24V±5% 50mA below

B2

12V±5% 50mA below

B3

10V±5% 50mA below

Communication (option) (the communication protocol is optional through the instrument parameters: Modbus-RTU or TC-ASCII protocol)

S1

The RS232 interface(only AH AS B size)

S2

The RS485 interface

Power Specifications

V0

100-240V AC 50/60 Hz

V1

10-24VAC 50/60Hz;10-24VDC 

Note : A size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note : B size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note :C size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3R or T4 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected one of the two, and communication can only select RS485 mode (i.e. S2)

Note : D size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected from one of the two, and communication can only select RS485 mode (i.e. S2)

Note : E size instrument

You can choose two out of three for 1-point switching input, transmission output and communication functions (communication only supports RS485 at this time)

When 2-point alarm output is selected2, external power supply cannot be selected; 1-point switching input, transmission output and communication functions can be selected two out of three (communication only supports RS485 at this time)


  • Application
Prev:no morer