1、 Product Overview
WOA-A series magnetic induction rotation angle position sensor is a non-contact encoder used to measure the rotation position of the
motor. The magnetic induction rotation angle position sensor product adopts the anisotropic magnetoresistance (AMR) sensor independently developed by Mirang Technology, and adds signal conditioning and algorithms to calculate the angle.
2、 Product features
● Signal output: RS485 half duplex communication, 4-20mA, 0-5V, 0-10V
● Support speed of 6000rpm
● Output resolution: 17 resolution
● Temperature range: -30 ℃ to 85 ℃
● Small size
● Strong anti pollution ability
● High accuracy, reaching 0.02 degrees
3、 Application field
● Servo control system
● Robot arm
● Position measurement
● Industrial automation control
● DC motor
4、 Electrical technical specifications
Item | Content | Note |
Power supply | DC 5V(RS485)/DC12V~DC24V (Voltage/Current/RS485) | Fluctuation below 5% |
Power supply voltage VCC Consumption current | 40mA | Excluding mutation situations |
Output Signal | 0-5V/0-10V/4-20mA/RS485 | |
Linear accuracy | ≤0.02° | |
Resolution | 17 bit | |
Allow rotation speed | ≤6000rpm | |
Number of Circle | 1-32767 Circle (can be calibrated freely within the range) | |
Input output form | Differential line driver/receiver | |
Ambient Temperature | -30℃~85℃ |
5、 Naming rules
6、 Wiring method
Cable color | Function | Note |
Red | Power + VCC | DC 5V(RS485)/DC12V~DC24V(Voltage/Current/RS485) |
Black | Power - GND | |
Blue | D+/OUT+ | RS485-A/OUT+ |
White | D-/OUT- | RS485-B/OUT- |
Shield | Connecting casing |
7、 Mechanical installation dimensions
8、 Communication specifications
Item | Content | Note |
Transmission | Half duplex serial communication | RS485 |
Communication rate | 9600bps | Default |
Synchronous mode | Start stop synchronization (8-bit data, 1-bit stop) | |
Bit sequence | LSB First | |
Transmission error verification | CRC verification | CRC polynomial CRC16+1 |
Note: Due to the initialization of the internal circuit after turning on the power, please input the command after powering on for 50ms. When the BAT voltage is less than 2.8V, the multi turn data will be reset to zero.