TEL:

180 3818 6775

Announcement:

Product

大兴安岭Sensors

more+

Linear Position Sensor

more+

大兴安岭KTC1/LWHPull Rod Linear Displacement Sensor 大兴安岭KTF Slider Displacement Sensor 大兴安岭KTF1 Slider Displacement Sensor 大兴安岭KTR11/12,KTR2 Spring Self-return Position Potentiometer 大兴安岭KTM Miniature Pull Rod Displacement Sensor 大兴安岭KTC2 Pull Rod Linear Displacement Sensor 大兴安岭KPC1H Hersman Plug out Pull-rod Resistance 大兴安岭KPC1 Articulated Electronic Ruler 大兴安岭KPM23 Small Articulated Resistance Sensor 大兴安岭KPM22 Small Articulated Resistance Sensor 大兴安岭KPM18 Small Articulated Resistance Sensor 大兴安岭KPM16 Shock Travel Sensor 大兴安岭KPM12 Shock Travel Sensor 大兴安岭KPM12R1/KPM12R2 Self-reset Resistance Sensor 大兴安岭WY-01 Resistive Displacement Sensor 大兴安岭WDL Rod Type Displacement Sensor 大兴安岭KSE Pull Rod Displacement Sensor 大兴安岭KPF Flange Displacement Sensor 大兴安岭KFM Micro Slider Type Resistance Sensor 大兴安岭KSP Circular Tube Miniature Self-reset 大兴安岭KSC Square Tube Miniature Self-reset Displacement sensor 大兴安岭KS8X Micro Self-resetting Displacement Sensor 大兴安岭KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 大兴安岭KST Self resetting displacement sensor 大兴安岭KSD Linear Position Sensor 13FLP 大兴安岭KPFZ Flange-mounted self-resetting resistance ruler 大兴安岭LEP displacement sensorwith Waterproof and dustproof 大兴安岭KEP Brushless Sensor with Waterproof and Dustproof 大兴安岭LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 大兴安岭KPM9 Mini Type Pull Rod Displacement Sensor 大兴安岭KSE Rod type displacement sensor 大兴安岭KSF Micro Slide Type Displacement Sensor 大兴安岭KSN Self-resetting Displacement Sensor
Rope/wire displacement sensor

more+

大兴安岭MPS-XXXS Pull Wire Displacement Sensor 大兴安岭MPS-XXS Pull Wire Displacement Sensor 大兴安岭MPS-XS Pull Wire Displacement Sensor 大兴安岭MPS-S Pull Wire Displacement Sensor 大兴安岭MPS-M Pull Wire Displacement Sensor 大兴安岭MPS-L Pull Wire Displacement Sensor 大兴安岭MPS-XL Pull Wire Displacement Sensor 大兴安岭MPSFS2-S Waterproof Absolute Wire Rope Sensor 大兴安岭MPSFS2-M Waterproof Absolute Wire Rope Sensor 大兴安岭MPSFS2-L Waterproof Absolute Wire Rope Sensor 大兴安岭MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 大兴安岭MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 大兴安岭MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 大兴安岭MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 大兴安岭MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 大兴安岭MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 大兴安岭MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 大兴安岭MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 大兴安岭MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 大兴安岭SM-S Pull Wire Displacement Sensor 大兴安岭SM-M Pull Wire Displacement Sensor 大兴安岭WEP-S Pull Wire Displacement Sensor 大兴安岭WEP-M Pull Wire Displacement Sensor 大兴安岭WS-S Pull Wire Displacement Sensor 大兴安岭MDS-S Pull Wire Displacement Sensor 大兴安岭MPS-XS Magnetic Mounting Rope Displacement Sensor 大兴安岭MPS-L Magnetic Draw Wire Displacement Sensor 大兴安岭MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 大兴安岭MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 大兴安岭MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor
大兴安岭Fully Automatic Lubricating Oil Pump

more+

大兴安岭Electric Automatic Oil Pump / Manual Oil Pump

more+

大兴安岭MIRAN MR-2202-2(2L) Thin Oil Lubrication Pump Controlled by PLC Type 大兴安岭MIRAN MR-2232-2(2L) Self-control Electric Oil Lubrication Pump 大兴安岭MIRAN MR-2202-3(3L) Thin Oil Electric Lubrication Pump 大兴安岭MIRAN MR-2232-3(3L)Self-control Electric Oil Lubrication Pump 大兴安岭MIRAN MRG-2202(4L) Asynchronous Dynamo Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 大兴安岭MIRAN MRG-2232(4L) Asynchronous Dynamo Grease and Thin Oil Lubrication Intergrated Pump 大兴安岭MIRAN MRG-3202(5L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 大兴安岭MGH-1205-100T Semi-automatic Butter Lubrication Pump 大兴安岭MIRAN MRG-3205(5L) Grease and Thin Oil Intergratd Pump by PLC Type 大兴安岭MIRAN MRG-3232(5L)Grease and Thin Oil Lubrication Intergrated Pump 大兴安岭MRG-3202(3L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 大兴安岭MIRAN MRG-3235(5L) Grease and Thin Oil Lubrication Electric Intergrated Pump 大兴安岭MRG-3232(3L) Self-control Grease and Thin Oil Lubrication Pump 大兴安岭MIRAN MRG-5202(3L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 大兴安岭MRG-5232-41 Self-control Grease and Thin Oil Lubrication Pump 大兴安岭MIRAN MRG-5202-41 (4L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 大兴安岭MRG-5202(5L) Self-control Grease and Thin Oil Lubrication Pump with PLC Type 大兴安岭MRG-5232(5L) Self-control Grease and Thin Oil Lubrication Pump 大兴安岭MRH-1202-100T Semi-automatic Grease Lubrication Pump 大兴安岭MRH-1232-100TB Automatical Grease Lubrication Pump 大兴安岭MGH-1202-100T Semi-automatic Butter Lubrication Pump 大兴安岭MGH-1232-100TB Self-control Butter Pump
Your current location is:Home>>大兴安岭Product>>大兴安岭Sensors>>Fixed inclinometer sensor

大兴安岭Fixed inclinometer sensor

  • Product classification:Fixed inclinometer sensor
  • Number of views:1067
  • QR code:
  • Release time:2024-02-27
  • Overview

1    Principle and overview of fixed inclinometer/inclinometer:

       The fixed inclinometer is a fixed inclinometer developed by our company based on high-precision six axis sensors combined with single-chip embedded systems. It is used to observe the relative horizontal biaxial tilt angle of slopes, foundation pits, railways, etc., and combined with automatic real-time monitoring systems, it can also be suitable for long-term monitoring of landslide geological activities. The multi-level setting of drilling can measure the inclination angle of each depth, convert the inclination angle into displacement, and is suitable for the deformation variables of concealed parts that are difficult to observe by conventional measurement methods.
1708929777599201[1].png

           The fixed inclinometer is composed of an electronic compartment (high-precision angle sensitive components and chipset), as well as  external stainless steel components, pulley components, etc. An external four core shielded wire leads out. Usually, the installation of fixed inclinometers also requires the installation of accessories, such as inclinometers, stainless steel wires, lifting rings, etc., which need to be configured reasonably according to the on-site situation.
1708930027219730[1].png



2    Technical parameters of fixed inclinometer/inclinometer:


Item

Parameter

Voltage Supply

+9V--28VDC

Working Current

14mA(+24VDC)

Working Temperature

-20℃--80℃

Testing Range

XY Dual Axis ±60°

Resolution ratio

0.01°

Accuracy

±0.05°

Output Signal

RS485

Protocol

Modbus—RTU

Guide wheels distance

500mm

Cable Length

2m default


Wiring Definition

Brown:Supply(+)

Black:Supply(-)

Blue:458(A)

White:485(B)



3   Product Naming Rules


企业微信截图_17089312124177.png


             Under actual installation conditions, the direction of the guide wheel (i.e. the X-axis direction) should be installed towards the expected tilt direction. After the inclinometer is placed in the designated position of the inclinometer tube, the initial angle value needs to be determined. After installation, read the current angle value of the inclinometer. After the data stabilizes, take the average of the current position angle as the initial angle value of the sensor, denoted as Angle_X0, Angle_Y0. Afterwards, the angle values of all sensors are calculated based on this initial angle value.

            The horizontal displacement of the initial value in the X-axis direction is represented by DX0, the displacement in the y-axis direction is represented by DY0, and the overall displacement is represented by D0. The angle data measured by sensors, Angle_X and Angle_Y, are calculated using a trigonometric function at the gauge length L (i.e. the wheelbase before adjacent sensors) to obtain the horizontal displacement at the measured gauge length. The displacement direction is based on the sign of the angle data measured on the X and Y axes, with+indicating positive direction and - indicating negative direction. In practical use, data analysis is conducted based on relative displacement, which refers to the displacement of each measurement point relative to its initial position. Reference for displacement calculation method :


Displacement in initial direction of  X-axis :  DX0 = L*sin(Angle_X0)

Displacement in initial direction of  Y-axis :  DY0 = L*sin(Angle_Y0)

Overall displacement at initial position :   D0 = (DX0²+DY0)½


Horizontal displacement in the X-axis direction :  DXn = L*sin(Angle_Xn)

Relative displacement in the X-axis direction :  △DXn = DXn - DX0


Horizontal displacement in the Y-axis direction :  DYn = L*sin(Angle_Yn)

Relative displacement in the Y-axis direction :  △DYn = DYn - DY0