MPS-XXXS Pull Wire Displacement Sensor MPS-XXS Pull Wire Displacement Sensor MPS-XS Pull Wire Displacement Sensor MPS-S Pull Wire Displacement Sensor MPS-M Pull Wire Displacement Sensor MPS-L Pull Wire Displacement Sensor MPS-XL Pull Wire Displacement Sensor MPSFS2-S Waterproof Absolute Wire Rope Sensor MPSFS2-M Waterproof Absolute Wire Rope Sensor MPSFS2-L Waterproof Absolute Wire Rope Sensor MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor SM-S Pull Wire Displacement Sensor SM-M Pull Wire Displacement Sensor WEP-S Pull Wire Displacement Sensor WEP-M Pull Wire Displacement Sensor WS-S Pull Wire Displacement Sensor MDS-S Pull Wire Displacement Sensor MPS-XS Magnetic Mounting Rope Displacement Sensor MPS-L Magnetic Draw Wire Displacement Sensor MPS-M Plastic Protective Cover Pull Wire Displacement Sensor MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor
Fully Automatic Lubricating Oil Pump

more+

Electric Automatic Oil Pump / Manual Oil Pump

more+

Your current location is:Home>>Product>>Sensors>>Magnet Resistive Displacement Sensor

PME12 Magnet Resistive Displacement Sensor

  • Product classification:Magnet Resistive Displacement Sensor
  • Number of views:1291
  • QR code:
  • Release time:2023-11-13
  • Overview

Magnet Resistive Displacement Sensor: PME12

PME12磁阻式位移传感器


Technical Parameters

Effective electrical travel(C.E.U)

50~1000mm

independent linearity(in C.E.U.)

0.05%

Displacement efficiency

≤5m/s

Greater acceleration

≤10m/s²

DIN vibration IEC 68T2-6

12g,10...2000Hz

Pointer resistance

≤0.5N

Impact test DIN IEC68T2-27

50g,11ms,click

Displacement sensitivity (without hysteresis)

0.05~0.1mm

Resistance tolerance

±10%

Recommended pointer current

<0.1uA

Larger pointer current, under poor performance conditions

10mA

Greater application voltage

36V

Dielectric Strength

>100MΩ当500V=,1bar,2s

Dielectric Strength

<100uA当500V=,50Hz,2s,1bar

Runs

一亿次

Environmental protection level

IP67

Actual temperature coefficient of output voltage

<1.5ppm/℃

Working temperature range

-40...+120℃

Storage temperature range

-50...+150℃


Install Dimension:

PME12尺寸图.png

Main features:

  • The PME12 linear displacement sensor adopts an unobstructed shaft design and a sealing grade of IP67, which can meet the displacement measurement needs in dusty or oily environments, humid environments, or temporary immersion conditions.

  • The PME series products are a new type of displacement measurement sensor based on the connection between external electromagnetic actuators and internal measuring verniers.

  • By replacing the resistance axis in traditional displacement sensors with a magnetic cursor, the sensor structure is more compact.

  • After exceeding the theoretical electrical stroke, there is no electrical signal change, making installation simpler.

  • After exceeding the theoretical electrical stroke, there is no electrical signal change, making installation simpler. This system sensor is suitable for displacement measurement in various air pressure environments, with a working pressure of ≤ 2 5MPa.

Range selection:50mm-1000mm is optional(mm):


50

100

150

200

250

300

350

400

450

500

550

600

650

700

750

800

850

900

950

1000

important reminder: The data reported in the table of contents, including straight lines and temperature coefficients, are only valid for metric devices with a larger flow rate of ≤ 10uA through the pointer circuit IC

  • Application