TEL:

180 3818 6775

Announcement:

Product

阿拉尔Sensors

more+

Linear Position Sensor

more+

阿拉尔KTC1/LWHPull Rod Linear Displacement Sensor 阿拉尔KTF Slider Displacement Sensor 阿拉尔KTF1 Slider Displacement Sensor 阿拉尔KTR11/12,KTR2 Spring Self-return Position Potentiometer 阿拉尔KTM Miniature Pull Rod Displacement Sensor 阿拉尔KTC2 Pull Rod Linear Displacement Sensor 阿拉尔KPC1H Hersman Plug out Pull-rod Resistance 阿拉尔KPC1 Articulated Electronic Ruler 阿拉尔KPM23 Small Articulated Resistance Sensor 阿拉尔KPM22 Small Articulated Resistance Sensor 阿拉尔KPM18 Small Articulated Resistance Sensor 阿拉尔KPM16 Shock Travel Sensor 阿拉尔KPM12 Shock Travel Sensor 阿拉尔KPM12R1/KPM12R2 Self-reset Resistance Sensor 阿拉尔WY-01 Resistive Displacement Sensor 阿拉尔WDL Rod Type Displacement Sensor 阿拉尔KSE Pull Rod Displacement Sensor 阿拉尔KPF Flange Displacement Sensor 阿拉尔KFM Micro Slider Type Resistance Sensor 阿拉尔KSP Circular Tube Miniature Self-reset 阿拉尔KSC Square Tube Miniature Self-reset Displacement sensor 阿拉尔KS8X Micro Self-resetting Displacement Sensor 阿拉尔KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 阿拉尔KST Self resetting displacement sensor 阿拉尔KSD Linear Position Sensor 13FLP 阿拉尔KPFZ Flange-mounted self-resetting resistance ruler 阿拉尔LEP displacement sensorwith Waterproof and dustproof 阿拉尔KEP Brushless Sensor with Waterproof and Dustproof 阿拉尔LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 阿拉尔KPM9 Mini Type Pull Rod Displacement Sensor 阿拉尔KSE Rod type displacement sensor 阿拉尔KSF Micro Slide Type Displacement Sensor 阿拉尔KSN Self-resetting Displacement Sensor
Rope/wire displacement sensor

more+

阿拉尔MPS-XXXS Pull Wire Displacement Sensor 阿拉尔MPS-XXS Pull Wire Displacement Sensor 阿拉尔MPS-XS Pull Wire Displacement Sensor 阿拉尔MPS-S Pull Wire Displacement Sensor 阿拉尔MPS-M Pull Wire Displacement Sensor 阿拉尔MPS-L Pull Wire Displacement Sensor 阿拉尔MPS-XL Pull Wire Displacement Sensor 阿拉尔MPSFS2-S Waterproof Absolute Wire Rope Sensor 阿拉尔MPSFS2-M Waterproof Absolute Wire Rope Sensor 阿拉尔MPSFS2-L Waterproof Absolute Wire Rope Sensor 阿拉尔MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 阿拉尔MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 阿拉尔MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 阿拉尔MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 阿拉尔MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 阿拉尔MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 阿拉尔MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 阿拉尔MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 阿拉尔MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 阿拉尔SM-S Pull Wire Displacement Sensor 阿拉尔SM-M Pull Wire Displacement Sensor 阿拉尔WEP-S Pull Wire Displacement Sensor 阿拉尔WEP-M Pull Wire Displacement Sensor 阿拉尔WS-S Pull Wire Displacement Sensor 阿拉尔MDS-S Pull Wire Displacement Sensor 阿拉尔MPS-XS Magnetic Mounting Rope Displacement Sensor 阿拉尔MPS-L Magnetic Draw Wire Displacement Sensor 阿拉尔MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 阿拉尔MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 阿拉尔MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor
阿拉尔Fully Automatic Lubricating Oil Pump

more+

阿拉尔Electric Automatic Oil Pump / Manual Oil Pump

more+

阿拉尔MIRAN MR-2202-2(2L) Thin Oil Lubrication Pump Controlled by PLC Type 阿拉尔MIRAN MR-2232-2(2L) Self-control Electric Oil Lubrication Pump 阿拉尔MIRAN MR-2202-3(3L) Thin Oil Electric Lubrication Pump 阿拉尔MIRAN MR-2232-3(3L)Self-control Electric Oil Lubrication Pump 阿拉尔MIRAN MRG-2202(4L) Asynchronous Dynamo Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 阿拉尔MIRAN MRG-2232(4L) Asynchronous Dynamo Grease and Thin Oil Lubrication Intergrated Pump 阿拉尔MIRAN MRG-3202(5L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 阿拉尔MGH-1205-100T Semi-automatic Butter Lubrication Pump 阿拉尔MIRAN MRG-3205(5L) Grease and Thin Oil Intergratd Pump by PLC Type 阿拉尔MIRAN MRG-3232(5L)Grease and Thin Oil Lubrication Intergrated Pump 阿拉尔MRG-3202(3L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 阿拉尔MIRAN MRG-3235(5L) Grease and Thin Oil Lubrication Electric Intergrated Pump 阿拉尔MRG-3232(3L) Self-control Grease and Thin Oil Lubrication Pump 阿拉尔MIRAN MRG-5202(3L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 阿拉尔MRG-5232-41 Self-control Grease and Thin Oil Lubrication Pump 阿拉尔MIRAN MRG-5202-41 (4L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 阿拉尔MRG-5202(5L) Self-control Grease and Thin Oil Lubrication Pump with PLC Type 阿拉尔MRG-5232(5L) Self-control Grease and Thin Oil Lubrication Pump 阿拉尔MRH-1202-100T Semi-automatic Grease Lubrication Pump 阿拉尔MRH-1232-100TB Automatical Grease Lubrication Pump 阿拉尔MGH-1202-100T Semi-automatic Butter Lubrication Pump 阿拉尔MGH-1232-100TB Self-control Butter Pump
Your current location is:Home>>阿拉尔Product>>阿拉尔Sensors>>阿拉尔Transfer module and digital display instrument

阿拉尔XSEW Display controller digital display (single channel)

  • Product classification:Transfer module and digital display instrument
  • Number of views:1042
  • QR code:
  • Release time:2023-11-15
  • Overview

XSEW Digital Display Instrument

0.05 level precision, measurement and control speed of 10 ~400 times per second can be set
Display range-99999~99999
Analog quantity is universal input, selected by setting
The 1-4-point alarm output is optional. It includes seven basic alarm methods, including measurement upper limit, measurement lower limit, deviation upper limit, deviation upper limit, deviation absolute value lower limit, fault alarm and four standby alarm methods.(Standby alarm mode: when the measured value is in the output interval, when the measured value enters the non-output interval, then the normal alarm)
Higher degree of standardization, rich functions. Including: input signal fault processing, measurement value clearance, peak, valley value acquisition, 10 section broken line correction and other functions
Optional transmission, communication

content

Code description

XSEW-

0.05 level measurement accuracy;Measurement and control speed is 10 times per second

Dimension

AH

160×80×125      Hole Size:152×76 (Note①)

CH

96×48×82       Hole Size:92×45 (Note②)

 

Panel specifications


Single 6-digit LED display

 Alarm(option)(250V AC/3A,resistive load)

AH

T1~T4

1~4 point relay output, are normally open and closed double contacts

 

01~04

Alarm is OC door output (voltage should be less than 40VDC and current should be less than 40 mA)

CH

T1~T2

1~2 point relay output, are normally open and closed double contacts

01~02

Alarm is OC door output (voltage should be less than 40VDC and current should be less than 40 mA)

T3

3 point relay output is a single open contact.

03

Alarm is OC door output (voltage should be less than 40VDC and current should be less than 40 mA)

Contact input (optional)

K

1 point external switch quantity input for reset

Transmitting (optional)

(resolution: 1/3000; load capacity: 600Ω)(Suitable for the measurement and control speed of 200 times per second and above the transmission speed)

A1

Current output(4-20)mA、(0-10)mA、(0-20)mA

A2

Voltage output(1-5)V、(0-5)V

A3

Voltage output(0-10)V

A4

 

Voltage output (-5V-+5V)

A5

Voltage output (-10V-10V)

Quick delivery (optional)

F

Suitable for the measurement and control speed of 200 times per second and above the transmission speed

External power supply (optional)

B1

24V±5% 50mA below

B2

12V±5% 50mA below

B3

10V±5% 50mA below

Communication (option)

(Optional via instrument parameters: Modbus-RTU or TC-ASCII communication protocol)

S1

RS232 interface (only AH size)

S2

RS485 interface

Power Specifications

V0

100-240V AC 50/60 Hz

V1

10-24VAC 50/60Hz;10-24VDC 

Note①:A size instrument

When selecting 1-point switching input, the instrument’s transmission output and communication functions can only be selected from one of the two.
Note②:C size instrument
When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (communication only supports RS485 at this time)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)


单通道XSEW显示控制器数显表安装尺寸

Ⅵ、Single channel XSEW display controller Digit Instrument

Installation precautions
1 )Please avoid the installation in the following places: 

1.1:Because of the drastic temperature change, it may be exposed places
1.2:Places where corrosive gases and combustible gases are produced
1.3:Where direct vibration or may impact the product
1.4:Dust, salt, metal powder more places
1.5:Clutter interference, prone to static electricity, magnetic field, noise place

1.6: Air conditioning or heating air flow blowing directly to the place

1.7:  A place where the sunlight shines directly

1.8: Due to thermal radiation and other possible thermal accumulation of places

(2)  When installing, please consider the following points:
2.1:In order not to hinder heat dissipation, do not block the surroundings of this product, do not block the ventilation openings, and leave sufficient ventilation space.
2.2:Considering wiring and maintenance, please ensure there is more than 50mm of space above and below the instrument.
2.3:Please installing installation directly above the high heat meter (heater, transformer, semiconductor operator, high power resistance).
2.4:If the ambient temperature is above 50℃, please use a forced fan or a cooler, but do not let the cooling air blow directly to the instrument.
2.5:In order to improve noise resistance and safety, please keep away from high pressure machine, power line, power machine for installation.


Ⅵ:Single channel XSEW display controller digit instrument wiring precautions

In order to avoid the influence of noise interference, please keep the input signal line away from the instrument power line, power power line and load line.

Ensure that the instrument power supply is not affected by the noise of the power supply when wiring. Where noise is susceptible, use a noise filter.

- Please twist the wire material into a twist shape. The shorter the pitch of the twist, the better the noise defense effect.
- Be sure to install the noise filter on the ground disk surface, and minimize the wiring between the output side of the noise filter and the power terminal.
- Please do not install the fuse, switch, etc. on the output side of the noise filter, otherwise the effect of the filter will be reduced.

Note: There is no fuse inside this instrument. For fuse-required occasions, please set up separately: recommended fuse specifications:

- Rated voltage 250V, time delay fuse of rated current 1A

-  Please use the power supply that meets the power supply specification.

-  Please avoid mixing the interference in the measurement circuit

- The measurement circuit is separated from the power cord (power circuit) or the ground circuit.
- For the interference of static electricity, the use of shielding line effect is good.

- To prevent misoperation, please do not attach any wires to the unused terminals.


  • Application