阿拉尔KTC1/LWHPull Rod Linear Displacement Sensor 阿拉尔KTF Slider Displacement Sensor 阿拉尔KTF1 Slider Displacement Sensor 阿拉尔KTR11/12,KTR2 Spring Self-return Position Potentiometer 阿拉尔KTM Miniature Pull Rod Displacement Sensor 阿拉尔KTC2 Pull Rod Linear Displacement Sensor 阿拉尔KPC1H Hersman Plug out Pull-rod Resistance 阿拉尔KPC1 Articulated Electronic Ruler 阿拉尔KPM23 Small Articulated Resistance Sensor 阿拉尔KPM22 Small Articulated Resistance Sensor 阿拉尔KPM18 Small Articulated Resistance Sensor 阿拉尔KPM16 Shock Travel Sensor 阿拉尔KPM12 Shock Travel Sensor 阿拉尔KPM12R1/KPM12R2 Self-reset Resistance Sensor 阿拉尔WY-01 Resistive Displacement Sensor 阿拉尔WDL Rod Type Displacement Sensor 阿拉尔KSE Pull Rod Displacement Sensor 阿拉尔KPF Flange Displacement Sensor 阿拉尔KFM Micro Slider Type Resistance Sensor 阿拉尔KSP Circular Tube Miniature Self-reset 阿拉尔KSC Square Tube Miniature Self-reset Displacement sensor 阿拉尔KS8X Micro Self-resetting Displacement Sensor 阿拉尔KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 阿拉尔KST Self resetting displacement sensor 阿拉尔KSD Linear Position Sensor 13FLP 阿拉尔KPFZ Flange-mounted self-resetting resistance ruler 阿拉尔LEP displacement sensorwith Waterproof and dustproof 阿拉尔KEP Brushless Sensor with Waterproof and Dustproof 阿拉尔LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 阿拉尔KPM9 Mini Type Pull Rod Displacement Sensor 阿拉尔KSE Rod type displacement sensor 阿拉尔KSF Micro Slide Type Displacement Sensor 阿拉尔KSN Self-resetting Displacement Sensor
Rope/wire displacement sensor

more+

阿拉尔MPS-XXXS Pull Wire Displacement Sensor 阿拉尔MPS-XXS Pull Wire Displacement Sensor 阿拉尔MPS-XS Pull Wire Displacement Sensor 阿拉尔MPS-S Pull Wire Displacement Sensor 阿拉尔MPS-M Pull Wire Displacement Sensor 阿拉尔MPS-L Pull Wire Displacement Sensor 阿拉尔MPS-XL Pull Wire Displacement Sensor 阿拉尔MPSFS2-S Waterproof Absolute Wire Rope Sensor 阿拉尔MPSFS2-M Waterproof Absolute Wire Rope Sensor 阿拉尔MPSFS2-L Waterproof Absolute Wire Rope Sensor 阿拉尔MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 阿拉尔MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 阿拉尔MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 阿拉尔MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 阿拉尔MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 阿拉尔MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 阿拉尔MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 阿拉尔MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 阿拉尔MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 阿拉尔SM-S Pull Wire Displacement Sensor 阿拉尔SM-M Pull Wire Displacement Sensor 阿拉尔WEP-S Pull Wire Displacement Sensor 阿拉尔WEP-M Pull Wire Displacement Sensor 阿拉尔WS-S Pull Wire Displacement Sensor 阿拉尔MDS-S Pull Wire Displacement Sensor 阿拉尔MPS-XS Magnetic Mounting Rope Displacement Sensor 阿拉尔MPS-L Magnetic Draw Wire Displacement Sensor 阿拉尔MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 阿拉尔MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 阿拉尔MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor
阿拉尔Fully Automatic Lubricating Oil Pump

more+

阿拉尔Electric Automatic Oil Pump / Manual Oil Pump

more+

阿拉尔MIRAN MR-2202-2(2L) Thin Oil Lubrication Pump Controlled by PLC Type 阿拉尔MIRAN MR-2232-2(2L) Self-control Electric Oil Lubrication Pump 阿拉尔MIRAN MR-2202-3(3L) Thin Oil Electric Lubrication Pump 阿拉尔MIRAN MR-2232-3(3L)Self-control Electric Oil Lubrication Pump 阿拉尔MIRAN MRG-2202(4L) Asynchronous Dynamo Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 阿拉尔MIRAN MRG-2232(4L) Asynchronous Dynamo Grease and Thin Oil Lubrication Intergrated Pump 阿拉尔MIRAN MRG-3202(5L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 阿拉尔MGH-1205-100T Semi-automatic Butter Lubrication Pump 阿拉尔MIRAN MRG-3205(5L) Grease and Thin Oil Intergratd Pump by PLC Type 阿拉尔MIRAN MRG-3232(5L)Grease and Thin Oil Lubrication Intergrated Pump 阿拉尔MRG-3202(3L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 阿拉尔MIRAN MRG-3235(5L) Grease and Thin Oil Lubrication Electric Intergrated Pump 阿拉尔MRG-3232(3L) Self-control Grease and Thin Oil Lubrication Pump 阿拉尔MIRAN MRG-5202(3L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 阿拉尔MRG-5232-41 Self-control Grease and Thin Oil Lubrication Pump 阿拉尔MIRAN MRG-5202-41 (4L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 阿拉尔MRG-5202(5L) Self-control Grease and Thin Oil Lubrication Pump with PLC Type 阿拉尔MRG-5232(5L) Self-control Grease and Thin Oil Lubrication Pump 阿拉尔MRH-1202-100T Semi-automatic Grease Lubrication Pump 阿拉尔MRH-1232-100TB Automatical Grease Lubrication Pump 阿拉尔MGH-1202-100T Semi-automatic Butter Lubrication Pump 阿拉尔MGH-1232-100TB Self-control Butter Pump
Your current location is:Home>>阿拉尔Product>>阿拉尔Sensors>>阿拉尔Transfer module and digital display instrument

阿拉尔XSK Display controller digital display (single channel)

  • Product classification:Transfer module and digital display instrument
  • Number of views:1144
  • QR code:
  • Release time:2023-11-15
  • Overview

XSK Digital Display Instrument

0.2 level accuracy, measurement and control speed can be set to 10 or 40 times per second,display range -1999~9999.
Dual four-digit digital tube display (main display + second display), of which the second display can display engineering quantity units, alarm values and other information.
Universal input, selected by setting up.
Optional 1 to 4 points alarm output. 7 basic alarm modes and 4 standby alarm modes: upper limit of standby, lower limit of standby, upper limit of standby deviation, and lower limit of standby deviation. (Standby alarm mode: means that when the instrument is powered on, it does not alarm when the measured value is in the output range. When the measured value enters the non-output range, a standby condition is established, and then the alarm is normal).
10-section polyline correction function.
1 point external switch input, used for clearing.
 Peak and valley value acquisition function.
Communication and transmission are optional.

content

Code description

XSK-

Universal analog input, 0.2 level display accuracy; measurement and control speed can be set to 10 or 40 times per second

Dimension

AH

160×80×125      Hole Size:152×76      (Note①)

AS

80×160×125       Hole Size:152×76   (Note①)

 

B

96×96×76       Hole Size:92×92      (Note②)

 

CH

96×48×82       Hole Size:92×45      (Note③)

 

CS

48×96×82       Hole Size:92×45      (Note③)

 

D

72×72×75       Hole Size:68×68      (Note④)

 

E

48×48×88       Hole Size:45.5×45.5  (Note⑤)

 

Panel specifications


Dual 4-digit LED display

Contact input (optional)

K

1 point external switch input for zeroing.(When AH and CH select K, communication and transmission can only choose one option; E size does not support K option)

Alarm(option)(250V AC/3A,resistive load)

A

T1~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

B

 

T1~T2

1~2 point relay output, are normally open and closed double contacts

 

T3~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

C

T1~T2

The output of 1~2 point alarm relay is normally open and closed double contacts

T3

The output of 3 alarm relay is single open contact

T3R

The output of the 3-point alarm relay is normally open and closed double contacts

T4

4 points alarm relay output, the first 3 points are single normally open contact, the fourth point is normally open normally closed double contact

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

D

T1~T2

1~2 point alarm relay output, 1 often open and close double contact; 1 often open contact

T3

3 points of alarm relay output, 1 point is normally open and normally closed double contact, and another 2 points are single and normally open contact

O1~O3

1-3 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

E

T1~T2

1~2 point alarm relay output, 1 point often open often closed contact, the other point is normally open contact

O1~O2

1-2 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

Transmitting (optional)

(resolution: 1/3000; load capacity: 600Ω)

A1

Current output(4-20)mA、(0-10)mA、(0-20)mA

A2

Voltage output(1-5)V、(0-5)V

A3

Voltage output(0-10)V

A4

Voltage output(-5V-+5V)

A5

Voltage output(-10V-+10V)

External power supply (optional)

B1

24V±5% 50mA below

B2

12V±5% 50mA below

B3

10V±5% 50mA below

Communication (option) (the communication protocol is optional through the instrument parameters: Modbus-RTU or TC-ASCII protocol)

S1

The RS232 interface(only AH AS B size)

S2

The RS485 interface

Power Specifications

V0

100-240V AC 50/60 Hz

V1

10-24VAC 50/60Hz;10-24VDC 

Note : A size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note : B size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note :C size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3R or T4 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected one of the two, and communication can only select RS485 mode (i.e. S2)

Note : D size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected from one of the two, and communication can only select RS485 mode (i.e. S2)

Note : E size instrument

You can choose two out of three for 1-point switching input, transmission output and communication functions (communication only supports RS485 at this time)

When 2-point alarm output is selected2, external power supply cannot be selected; 1-point switching input, transmission output and communication functions can be selected two out of three (communication only supports RS485 at this time)



  • Application