阿克苏KTC1/LWHPull Rod Linear Displacement Sensor 阿克苏KTC2 Pull Rod Linear Displacement Sensor 阿克苏KTF Slider Displacement Sensor 阿克苏KTF1 Slider Displacement Sensor 阿克苏KPC1 Articulated Electronic Ruler 阿克苏KPC1H Hersman Plug out Pull-rod Resistance 阿克苏KPM12R1/KPM12R2 Self-reset Resistance Sensor 阿克苏KPM16 Shock Travel Sensor 阿克苏KPM18 Small Articulated Resistance Sensor 阿克苏KPM22 Small Articulated Resistance Sensor 阿克苏KPM23 Small Articulated Resistance Sensor 阿克苏KPM12 Shock Travel Sensor 阿克苏WY-01 Resistive Displacement Sensor 阿克苏KSE Pull Rod Displacement Sensor 阿克苏KSC Square Tube Miniature Self-reset Displacement sensor 阿克苏KSP Circular Tube Miniature Self-reset 阿克苏KTR11/12,KTR2 Spring Self-return Position Potentiometer 阿克苏KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 阿克苏KSN Self-resetting Displacement Sensor 阿克苏KFM Micro Slider Type Resistance Sensor 阿克苏WDL Rod Type Displacement Sensor 阿克苏KPF Flange Displacement Sensor 阿克苏KTM Miniature Pull Rod Displacement Sensor 阿克苏KPFZ Flange-mounted self-resetting resistance ruler 阿克苏KSD Linear Position Sensor 13FLP 阿克苏KST Self resetting displacement sensor 阿克苏KS8X Micro Self-resetting Displacement Sensor 阿克苏KSE Rod type displacement sensor 阿克苏KPM9 Mini Type Pull Rod Displacement Sensor 阿克苏LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 阿克苏KEP Brushless Sensor with Waterproof and Dustproof 阿克苏LEP displacement sensorwith Waterproof and dustproof
Rope/wire displ...

more+

阿克苏WS-S Pull Wire Displacement Sensor 阿克苏MPS-XL Pull Wire Displacement Sensor 阿克苏MPS-L Pull Wire Displacement Sensor 阿克苏MPS-L Magnetic Draw Wire Displacement Sensor 阿克苏MPSFS2-S Waterproof Absolute Wire Rope Sensor 阿克苏LPS-M Pull Wire Displacement Sensor 阿克苏LPS-S Pull Wire Displacement Sensor 阿克苏MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 阿克苏MPS-XS Magnetic Mounting Rope Displacement Sensor 阿克苏MPSFS2-M Waterproof Absolute Wire Rope Sensor 阿克苏MPS-XXXS Pull Wire Displacement Sensor 阿克苏MPS-XXS Pull Wire Displacement Sensor 阿克苏MPS-XS Pull Wire Displacement Sensor 阿克苏MPS-S Pull Wire Displacement Sensor 阿克苏MPS-M Pull Wire Displacement Sensor 阿克苏MDS-S Pull Wire Displacement Sensor 阿克苏SM-S Pull Wire Displacement Sensor 阿克苏WEP-S Pull Wire Displacement Sensor 阿克苏WEP-M Pull Wire Displacement Sensor 阿克苏SM-M Pull Wire Displacement Sensor 阿克苏MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 阿克苏MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor 阿克苏MPSFS2-L Waterproof Absolute Wire Rope Sensor 阿克苏MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 阿克苏MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 阿克苏MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 阿克苏MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 阿克苏MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 阿克苏MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 阿克苏MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 阿克苏MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 阿克苏MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor
阿克苏Fully Automa...

more+

Your current location is:Home>>阿克苏Product>>Digital Indicator>>阿克苏XSK Digital Display Instrument

阿克苏XSK Digital Instrument

  • Product classification:XSK Digital Display Instrument
  • Number of views:985
  • QR code:
  • Release time:2023-11-14
  • Overview

XSK Digital Display Instrument

0.2 level accuracy, measurement and control speed can be set to 10 or 40 times per second,display range -1999~9999.
Dual four-digit digital tube display (main display + second display), of which the second display can display engineering quantity units, alarm values and other information.
Universal input, selected by setting up.
Optional 1 to 4 points alarm output. 7 basic alarm modes and 4 standby alarm modes: upper limit of standby, lower limit of standby, upper limit of standby deviation, and lower limit of standby deviation. (Standby alarm mode: means that when the instrument is powered on, it does not alarm when the measured value is in the output range. When the measured value enters the non-output range, a standby condition is established, and then the alarm is normal).
10-section polyline correction function.
1 point external switch input, used for clearing.
 Peak and valley value acquisition function.
Communication and transmission are optional.

content

Code description

XSK-

Universal analog input, 0.2 level display accuracy; measurement and control speed can be set to 10 or 40 times per second

Dimension

AH

160×80×125      Hole Size:152×76      (Note①)

AS

80×160×125       Hole Size:152×76   (Note①)

 

B

96×96×76       Hole Size:92×92      (Note②)

 

CH

96×48×82       Hole Size:92×45      (Note③)

 

CS

48×96×82       Hole Size:92×45      (Note③)

 

D

72×72×75       Hole Size:68×68      (Note④)

 

E

48×48×88       Hole Size:45.5×45.5  (Note⑤)

 

Panel specifications


Dual 4-digit LED display

Contact input (optional)

K

1 point external switch input for zeroing.(When AH and CH select K, communication and transmission can only choose one option; E size does not support K option)

Alarm(option)(250V AC/3A,resistive load)

A

T1~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

B

 

T1~T2

1~2 point relay output, are normally open and closed double contacts

 

T3~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

C

T1~T2

The output of 1~2 point alarm relay is normally open and closed double contacts

T3

The output of 3 alarm relay is single open contact

T3R

The output of the 3-point alarm relay is normally open and closed double contacts

T4

4 points alarm relay output, the first 3 points are single normally open contact, the fourth point is normally open normally closed double contact

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

D

T1~T2

1~2 point alarm relay output, 1 often open and close double contact; 1 often open contact

T3

3 points of alarm relay output, 1 point is normally open and normally closed double contact, and another 2 points are single and normally open contact

O1~O3

1-3 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

E

T1~T2

1~2 point alarm relay output, 1 point often open often closed contact, the other point is normally open contact

O1~O2

1-2 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

Transmitting (optional)

(resolution: 1/3000; load capacity: 600Ω)

A1

Current output(4-20)mA、(0-10)mA、(0-20)mA

A2

Voltage output(1-5)V、(0-5)V

A3

Voltage output(0-10)V

A4

Voltage output(-5V-+5V)

A5

Voltage output(-10V-+10V)

External power supply (optional)

B1

24V±5% 50mA below

B2

12V±5% 50mA below

B3

10V±5% 50mA below

Communication (option) (the communication protocol is optional through the instrument parameters: Modbus-RTU or TC-ASCII protocol)

S1

The RS232 interface(only AH AS B size)

S2

The RS485 interface

Power Specifications

V0

100-240V AC 50/60 Hz

V1

10-24VAC 50/60Hz;10-24VDC 

Note : A size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note : B size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note :C size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3R or T4 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected one of the two, and communication can only select RS485 mode (i.e. S2)

Note : D size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected from one of the two, and communication can only select RS485 mode (i.e. S2)

Note : E size instrument

You can choose two out of three for 1-point switching input, transmission output and communication functions (communication only supports RS485 at this time)

When 2-point alarm output is selected2, external power supply cannot be selected; 1-point switching input, transmission output and communication functions can be selected two out of three (communication only supports RS485 at this time)